3. Upgrade the primary system.
a. Make sure the primary system is running and the secondary system is shut
down.
b. Log into the primary system with the same administrator credentials that you
configured for the Insight Management service account credentials.
c. Use Failover Cluster Manager to take the Insight Management service offline.
In this paper, the Insight Management service is called cms-c16-matrix.
d. Use Failover Cluster Manager to bring only the Server Name and Disk Drives
resources in the Insight Management (cms-c16-matrix) service online on the
primary system.
e. Use Failover Cluster Manager to verify that the SQL Server service is online on
the primary system.
f. Run Administrative ToolsServices. Start the following Insight Management
services in the order listed, skipping any service not found in your system. The
services installed in your system depend on your Insight Management release
and your installed components:
i. Pegasus WMI Mapper
ii. HP Systems Insight Manager
iii. OpenSSH Server
iv. HP Version Control Repository Manager
v. HP Insight Control server migration Application Service
vi. HP Insight Control server migration Web Service
vii. HP Insight Control virtual machine management
viii. HP Application Discovery
ix. HP Global Workload Manager Central Management Server
x. HP Agentless Data Collector Service
xi. HP Agentless Collection for Linux Systems
xii. HP Capacity Advisor Data Service
xiii. HP Extensible Storage & Server Adapter
xiv. HP SPM Storage Module J2EE Service
xv. HP SPM Storage Module Service
xvi. HP Storage Provisioning Manager
xvii. HP Storage Provisioning Manager Service
xviii. HP Logical Server Automation
xix. RSScheduler