to another name (for example, First Install). Ignore any files you may find in the root folder
of this disk.
Note:
For installation of the secondary system, the path information given for the
Insight Management install locations must be identical to that given for the
primary system. Generally, all your inputs to the configuration screens
should be the same as for the primary system installation.
5. [ICG: Step 2–21] Repeat the previous Steps 3 through 14 of Installing Insight Management
components on the primary system.
6. Inspect the Insight Management installation directory for the Insight Control performance
management installation log, located at
C:\HPIC\logs\ICM_<installtimestamp>\ICPerf_V6.log. Toward the end of the file,
there may be entries similar to:
Schema created successfully
Integrating PMP Menu items & Status column to HPSIM... Checking SIM
running status...
Not running now. PMP Menu items & Status columns will be integrated
when SIM starts
You can also manually run ...\HP\Systems Insight Manager\lbin\
mxconfigrefresh after copying *.xml & *.properties files from
...\HP\Insight Control performance management\ to the ...\HP\Systems
Insight Manager\setup folder
If these entries appear, which suggest that the PMP configuration has not completed, then copy
the *.xml and *.properties files from the PMP installation directory to the Systems Insight Manager
setup folder.
7. Open the ~\Systems Insight Manager\config\database.props file (for example,
using Notepad) and record the database name corresponding to the
hp.Database.databaseName keyword.
Optional: Installing an Insight Management 7.0 Update
If you installed an Insight Management 7.0 update on the primary system, install the same update on
the secondary system at this point in the installation procedure. See
Appendix C: Applying Insight
Management Incremental Updates for more information about installing an update. See How to run
the Incremental Update Installer in Appendix C for details about running the incremental installer.
If you also installed Insight Management Software Patches on the primary system, install the same on
the secondary system at this point in the installation procedure. See
Appendix D: Applying Insight
Management Software Patches for more details.
Retargeting the Systems Insight Manager data source name on the
primary system (Optional)
Although Insight Management does not require the creation of an ODBC data source name for the
Systems Insight Manager database, some installations access System Insight Manager’s database