HP Virtual Connect Enterprise Manager 6.3.1 CLI Guide
Table Of Contents
- HP Insight Software Virtual Connect Enterprise Manager
- Contents
- 1 Getting Started
- 2 Using VCEMCLI
- 3 Using VCEM commands
- add profile
- set profile
- assign profile
- export profiles
- unassign profile
- add enet-connection
- set enet-connection
- remove enet-connection
- add fc-connection
- set fc-connection
- remove fc-connection
- add fcoe-connection
- set fcoe-connection
- remove fcoe-connection
- add iscsi-connection
- set iscsi-connection
- remove iscsi-connection
- set iscsi-boot-param
- remove iscsi-boot-param
- add server-port-map
- set server-port-map
- remove server-port-map
- poweroff devicebay
- poweron devicebay
- show power-status
- show job
- show version
- show vcem-status
- startvcdmaint
- cancelvcdmaint
- completevcdmaint
- 4 Error messages
- 5 Troubleshooting VCEMCLI
- VCEMCLI calls result in access denied errors
- VCEMCLI calls result in errors for invalid leading character or invalid characters
- VCEMCLI calls result in 404 errors
- API timeouts
- High CPU usage on the CMS server while running a VCEMCLI client
- Job reports failed status
- Completed with warning job status
- Unable to assign a profile to a Domain Group
- VC Domain reports Configuration Mismatch status
- VC Domain reports Expired License status
- Error on database operation occurs
- Failed to execute VCEM operation because VC firmware not supported
- Creating a server profile fails
- Server profile edit operation fails when target server is powered on
- Server profile job completed with success but changes have not occurred
- After a server profile assignment, some connections defined in the server profile are not functional
- Commands -add profile or -set profile error messages
- Command -add profile error messages
- Additional Troubleshooting Information and tools
- 6 Support and other resources
- Index

Table 37 VCEM server error messages and descriptions (continued)
Error message description
NOTE: The error message descriptions in this table use
[x] to represent variables in the error message output.
Error message number
There are more than one FCoE connection configured as
primary boot. Only one FCoE connection can be configured
as primary boot.
2747
There are more than one FCoE connection configured as
secondary boot. Only one FCoE connection can be
configured as secondary boot
2748
There is one FCoE connection configured as secondary
boot, but not one configured as primary boot.
2749
In the FCoE connection for interconnect bay , the selected
FC SAN fabric does not have a physical connection to this
port.
2750
In the FCoE connection for interconnect bay , the selected
FC SAN fabric does not exist. The FC SAN fabric must
2751
exist in the VC Domain Group to which the Server Profile
belongs.
Cannot configure FCoE connection because the specified
interconnect bay is invalid. A valid interconnect bay must
have a VC module that supports FCoE connections.
2752
In the FCoE connection for interconnect bay , the selected
port speed type is invalid. The valid values are {2}.
2753
In the FCoE connection for interconnect bay , the selected
port speed is invalid. The valid values are {2}.
2754
In the FCoE connection for interconnect bay , the custom
port speed is incorrect. The minimum and maximum port
2755
speeds cannot be empty. They must have the same value,
and the value must be a multiple of 100 Mb.
In the FCoE connection for interconnect bay , the custom
port speed is lower than the minimum allowed port speed
(Gb).
2756
In the FCoE connection for interconnect bay , the MAC
range type is not compatible with the addresses inside the
connection.
2757
In the FCoE connection for interconnect bay , the number
of MAC addresses is not correct. Each connection must
have only one MAC address.
2758
In the FCoE connection for interconnect bay , the
connection was replaced by a new one. To replace a
2759
connection, edit the Server Profile and delete the
connection, and then edit the Server Profile again and add
the new connection.
In the FCoE connection for interconnect bay , the WWN
range type is not compatible with the addresses inside the
connection.
2760
Invalid number of WWN addresses in the FCoE connection
for interconnect bay . VC Domains with multiple logical
2761
HBA ports per physical HBA port support up to 17
WWNN/WWPN pairs per physical port; otherwise, only
one WWNN/WWPN pair is supported per physical port.
80 Error messages