HP Virtual Connect Enterprise Manager 6.3.1 CLI Guide
Table Of Contents
- HP Insight Software Virtual Connect Enterprise Manager
- Contents
- 1 Getting Started
- 2 Using VCEMCLI
- 3 Using VCEM commands
- add profile
- set profile
- assign profile
- export profiles
- unassign profile
- add enet-connection
- set enet-connection
- remove enet-connection
- add fc-connection
- set fc-connection
- remove fc-connection
- add fcoe-connection
- set fcoe-connection
- remove fcoe-connection
- add iscsi-connection
- set iscsi-connection
- remove iscsi-connection
- set iscsi-boot-param
- remove iscsi-boot-param
- add server-port-map
- set server-port-map
- remove server-port-map
- poweroff devicebay
- poweron devicebay
- show power-status
- show job
- show version
- show vcem-status
- startvcdmaint
- cancelvcdmaint
- completevcdmaint
- 4 Error messages
- 5 Troubleshooting VCEMCLI
- VCEMCLI calls result in access denied errors
- VCEMCLI calls result in errors for invalid leading character or invalid characters
- VCEMCLI calls result in 404 errors
- API timeouts
- High CPU usage on the CMS server while running a VCEMCLI client
- Job reports failed status
- Completed with warning job status
- Unable to assign a profile to a Domain Group
- VC Domain reports Configuration Mismatch status
- VC Domain reports Expired License status
- Error on database operation occurs
- Failed to execute VCEM operation because VC firmware not supported
- Creating a server profile fails
- Server profile edit operation fails when target server is powered on
- Server profile job completed with success but changes have not occurred
- After a server profile assignment, some connections defined in the server profile are not functional
- Commands -add profile or -set profile error messages
- Command -add profile error messages
- Additional Troubleshooting Information and tools
- 6 Support and other resources
- Index

Table 37 VCEM server error messages and descriptions (continued)
Error message description
NOTE: The error message descriptions in this table use
[x] to represent variables in the error message output.
Error message number
all port connections are correctly pointing to a valid
network and then perform the operation again.
In the FC SAN connection for interconnect bay , the
selected FC SAN fabric does not have a physical
connection to this port.
2560
The server bay cannot be changed when updating an
assigned server profile.
2561
The entered MAC addresses is invalid. Verify it is well
formed (NN-NN-NN-NN-NN-NN, where N is a
hexadecimal digit (0-F)).
2562
The entered WWN addresses is invalid. Verify it is well
formed (NN:NN:NN:NN:NN:NN:NN:NN,
2563
NN-NN-NN-NN-NN-NN-NN-NN or
NNNNNNNNNNNNNNNN, where N is a hexadecimal
digit (0-F)).
The entered Logical Serial Number is invalid. Verify it is
well formed (VCX00NNNNN, VCX01NNNNN or
2564
VCYNNNNNNN, where N is a alpha-numeric digit (0-9
or A-Z)).
Cannot configure FC SAN connection because the specified
the interconnect bay number is invalid.
2601
Cannot configure FC SAN connection because the specified
FC SAN fabric does not exist or it cannot be assigned to
2602
the provided port. Each FC SAN fabric can only be
assigned to its corresponding port. Verify the provided FC
SAN fabric exists and can be assigned to the provided
port.
In the FC SAN connection for interconnect bay , the
selected port speed is invalid
2603
The target server bay is already in use by another server
profile.
2604
The target server bay does not exist or does not belong to
the same VC Domain Group that the server profile belongs.
2605
In the FC SAN connection for interconnect bay , the entered
boot target WWPN is not well formed. Valid format is
2606
xx:xx:xx:xx:xx:xx:xx:xx or xx-xx-xx-xx-xx-xx-xx-xx or
xxxxxxxxxxxxxxxx where each x represents a hexadecimal
digit.
In the FC SAN connection for interconnect bay , the
specified boot target LUN is invalid. Valid values are either
2607
a 3-digit decimal between 0 and 255, or a 13- to 16-digit
hexadecimal between 0 and FFFFFFFFFFFFFFFF.
Cannot set SAN boot settings because the specified boot
priority is not valid.
2608
Cannot create server profile because the specified server
profile does not contain the minimal required information.
2609
Verify the server profile has: - A unique name - A VC
Domain Group - At least two Ethernet network connection
physical ports defined - One FC SAN connection physical
port defined for each available FC SAN fabric module -
74 Error messages