HP Virtual Connect Enterprise Manager 6.3.1 CLI Guide

Table Of Contents
Table 19 Parameter descriptions for -add iscsi-connection (continued)
OptionalRequiredDescriptionParameter
value is 100Mb to the
maximum.
Output
The function returns the result of the add operation or a jobid if nb is specified.
Examples
Add a new iSCSI connection to the profile:
vcemcli -add iscsi-connection profilename MyNewProfile Network
SomeNetwork
Add a new iSCSI connection and leave it unassigned:
vcemcli -add iscsi-connection profilename MyNewProfile
Add a new iSCSI network connection and set the speed to Preferred:
vcemcli -add iscsi-connection profilename MyProfile network
MyNetwork speedtype Preferred
Add a new iSCSI network connection and set the speed to 2Gb:
vcemcli -add iscsi-connection profilename MyProfile network
MyNetwork speedtype customspeed 2000
Minimum Required Role Based Security
VCEM Group Operator
Remarks
The job status for the jobid can be obtained by executing VCEMCLI with the show job command
and providing the associated job ID. For more information see show job (page 60).
VC firmware 3.10 or later is required in order to use iSCSI. VC supports a maximum of 32 iSCSI
connections. The VC Domain must contain at least one of the following modules in the interconnect
bays in order to create an iSCSI connection:
FlexFabric 10GB/24-port module
Flex-10 Enet Module
42 Using VCEM commands