HP Virtual Connect Enterprise Manager 6.3.1 CLI Guide
Table Of Contents
- HP Insight Software Virtual Connect Enterprise Manager
- Contents
- 1 Getting Started
- 2 Using VCEMCLI
- 3 Using VCEM commands
- add profile
- set profile
- assign profile
- export profiles
- unassign profile
- add enet-connection
- set enet-connection
- remove enet-connection
- add fc-connection
- set fc-connection
- remove fc-connection
- add fcoe-connection
- set fcoe-connection
- remove fcoe-connection
- add iscsi-connection
- set iscsi-connection
- remove iscsi-connection
- set iscsi-boot-param
- remove iscsi-boot-param
- add server-port-map
- set server-port-map
- remove server-port-map
- poweroff devicebay
- poweron devicebay
- show power-status
- show job
- show version
- show vcem-status
- startvcdmaint
- cancelvcdmaint
- completevcdmaint
- 4 Error messages
- 5 Troubleshooting VCEMCLI
- VCEMCLI calls result in access denied errors
- VCEMCLI calls result in errors for invalid leading character or invalid characters
- VCEMCLI calls result in 404 errors
- API timeouts
- High CPU usage on the CMS server while running a VCEMCLI client
- Job reports failed status
- Completed with warning job status
- Unable to assign a profile to a Domain Group
- VC Domain reports Configuration Mismatch status
- VC Domain reports Expired License status
- Error on database operation occurs
- Failed to execute VCEM operation because VC firmware not supported
- Creating a server profile fails
- Server profile edit operation fails when target server is powered on
- Server profile job completed with success but changes have not occurred
- After a server profile assignment, some connections defined in the server profile are not functional
- Commands -add profile or -set profile error messages
- Command -add profile error messages
- Additional Troubleshooting Information and tools
- 6 Support and other resources
- Index

set fcoe-connection
The -set fcoe-connection command modifies an existing FCoE connection.
Syntax
set fcoe-connection –profilename <profileName>
-portnumber <PortNumber>
[-fabric <FabricName>]
[-speedtype <1Gb|2Gb|4Gb|8Gb|Custom|Disabled>]
[–customspeed <100–10000>]
[–bootpriority <priority>]
[–bootport <portName>]
[–bootlun <LUN>]
Parameters
Table 17 Parameter descriptions for -set fcoe-connection
OptionalRequiredDescriptionParameter
xThe name of the profile to
which the FcOE connection
will be assigned.
-profilename
xThe port number of the
connection.
-portnumber
xThe name of the FCoE SAN
fabric to associate with the
connection.
-fabric
xThe requested operational
speed for the server port.
-speedtype
Valid values include 1Gb,
2Gb, 4Gb,8Gb, custom,
and disabled. If the speed
type is custom, you can
configure any speed from
100Mb-10Gb in 100Mb
increments. The
-customspeed parameter
is required if the speed type
is custom and is the
user-defined speed for the
server port. Valid values
include 100Mb-10Gb
configured in 100Mb
increments The acceptable
value is 100 to 10000
Mb/s.
x
IMPORTANT: The
-customspeed parameter
is required if the speed type
is custom.
User-defined speed for the
server port. Valid values
include 100Mb-10Gb
configured in 100Mb
increments The acceptable
value is 100 to 10000
Mb/s.
-customspeed
xControls whether the FC
HBA port is enabled for
-bootpriority
SAN boot and affects the
BIOS boot order. Valid
values include the following:
• Usebios
• primary
38 Using VCEM commands