HP Insight Management 7.3 DMT White Paper

Note: VCEM automatically locks to the target CMS after migration.
If VCEM is to be uninstalled on the source CMS, first edit the registry on the source CMS. Locate the key
HKEY_LOCAL_MACHINESOFTWAREHewlett-PackardVirtual Connect Enterprise ManagerSettings, and
set checkVCDomain to false.
Step 9: Redeploying Shared Resource Domains when using Matrix OE Global Workload Manager
Users of Matrix OE Global Workload Manager must perform several additional steps. For
complete information, see the Matrix OE Global Workload Manager 7.3 User Guide.
1. If secure communications are desired, then secure communications between the target
CMS and all managed nodes.
2. Redeploy all previously deployed Shared Resource Domains.
Step 10: Migrating the Matrix OE orchestration users to the corresponding user groups on the target CMS when
using Matrix OE infrastructure orchestration
With the user names and passwords collected before the import operation, create the users on
the target CMS. This step is not required for domain users.
Associate the users with the corresponding Windows User Groups required by Matrix OE
infrastructure orchestration:
1. Go to StartAdministrative ToolComputer ManagementLocal Users and
Groups.
2. Add the Infrastructure Orchestration Administrator users to the HPIO_Administrators
group.
3. Add the Infrastructure Orchestration Architect users to the HPIO_Architects group.
4. Add the Infrastructure Orchestration regular users to the HPIO_Users group.
Step 11: If using Matrix OE recovery management, perform the following operations
1. Matrix OE Recovery Management's hp_ir.properties file contains the user-definable
property values. The file is located at 'conf' directory under Matrix Recovery
Management installed directory. An example full-path of the file is C:\Program
Files\HP\Insight Recovery\conf\hp_ir.properties.
If you have had reserved (copy) of the hp_ir.properties file from source CMS prior to the
Export/Import, use the reserved file to overwrite the existing hp_ir.properties file.
2. Use the following procedure to refresh the credentials for each EVA Storage
Management Server:
a. Navigate to the HP Recovery Management Storage Management Servers tab.
b. Select an EVA Storage Management Server, and click Edit.
c. Select the Refresh SIM Password box, and then click Save.
3. Copy the encrypted password files to manage HP 3PAR InServ storage systems from the
source CMS to the same location on the target CMS. On the source CMS, the files are
present in the STORAGE\3PAR\conf directory where Matrix recovery management is
installed. Use the following procedure to refresh the credentials for each 3PAR Storage
Management Server: