HP Insight Management 7.3 DMT White Paper

b. Verify that the System Name column includes entries for both the Failover
Cluster virtual server and the Systems Insight Manager virtual server. They may
be represented either by their virtual server name or IP address.
i. The Server Type of the Failover Cluster virtual server is Cluster.
ii. The Server Type of the Systems Insight Manager virtual server is Server.
c. Verify that no system of System Type Management Processor is associated with
either the Failover Cluster virtual server or the Systems Insight Manager virtual
server.
10. Navigate to OptionsDiscovery. The Systems Insight Manager discovery page appears.
11. Create or update the discovery task for the primary and secondary physical servers.
a. If the source CMS is a Cluster CMS and a Discover physical cluster nodes
discovery task is already configured:
i. Select and edit the Discover physical cluster nodes discovery task.
ii. In the ping inclusion range list box, change the IP addresses to be the IP
addresses of the primary and secondary nodes in the target cluster.
iii. Click the Credentials… button.
iv. The Sign-in tab is selected. Under Use these credentials ensure that the
credentials are set to the service account credentials you provided to the
Insight Management Installer on the target CMS, for example,
domain\username and password.
v. Clear the If these credentials fail box.
vi. Click OK.
vii. Click Save to complete.
b. If the source CMS is not a Cluster CMS and a Discover physical cluster nodes
discovery task is not configured:
i. Click New… to create a new discovery task.
ii. Select Discover a group of systems.
iii. In the Name field enter the task name, for example, Discover physical
cluster nodes.
iv. Under Schedule, clear the box used to select automatic scheduling.
v. In the ping inclusion range list box, enter the IP addresses of the primary
and secondary nodes.
vi. Click Credentials…
40