HP Insight Management 7.1 Update 1 Support Matrix - 60 day

1
This server supports only Power Capping. It does not support Dynamic Power Capping.
2
When you are implementing power capping for HP BladeSystems, HP recommends that you use Enclosure Dynamic
Power Capping set through the Onboard Administrator or Insight Control power management user interface. To use
Enclosure Dynamic Power Capping, you must upgrade your iLO 2 firmware to version 1.70 or later and iLO 3 to version
1.0 or later. HP recommends that you update your system ROM to version 10/1/2008 or later for iLO 2, and May
2010 or later for iLO 3 for G7 servers. For some older BL460c servers, the iLO 2 firmware might not be able to
automatically update the Dynamic Power Capping hardware circuit. In these instances, the Onboard Administrator will
compensate for the absence of the internal hardware circuit and continue to guarantee circuit protection.
Table 54 Requirements and capabilities for HP ProLiant DL servers
Intelligent
Power
Discovery
Data
Center
Power
Control
Calibrated
Maximum
Power
Power
Metering
Data
Center
Thermal
Mapping
Dynamic
Power
Capping
Power
Regulator
Minimum
system BIOS
version
Minimum
iLO
firmware
version
Server
model
NoneNoneProLiant
DL320
G6
1
2
5/1/2007iLO 2
version
ProLiant
DL360 G5
1.30 or
later
8/5/2008
3
ProLiant
DL360 G5
(with Quad
Core
“G-step
system
board)
P64
8/2/2009
iLO 2
version
ProLiant
DL360 G6
1.79 or
later
4/1/2010iLO 3
version 1.0
or later
ProLiant
DL360 G7
iLO 4
version
ProLiant
DL360e
Gen8 1.01 or
later
iLO 4
version
ProLiant
DL360p
Gen8 1.01 or
later
4
6/1/2005iLO 2
version
ProLiant
DL365 G1
1.20 or
later
2
2/21/2008iLO 2
version
ProLiant
DL365 G5
1.30 or
later
P63
1/27/2009
iLO 2
version
1.75
ProLiant
DL370 G6
2
5/1/2007iLO 2
version
ProLiant
DL380 G5
62 Hardware requirements and supported capabilities for Insight Control power management