Backing up and restoring HP Insight Management 7.3 Central Management Server (Windows)

Technical white paper | HP Insight Management 7.3
+---------------------------------------+
| Section 2 of 5 |
| Virtual Connect Enterprise Management |
+---------------------------------------+
Synchronizes VCEM with the state of the underlying VC Domains.
**** Analysis: Resolve conflicting resource assignments. ****
**** Section 2 of 5, phase 1 of 2 ****
Update or remove VCEM resources that conflict with the underlying VC
Domains.
Checking VC Domain str00106_vc_domain
Unassign VCEM profile TC1phy-net01_13cc9f628c6....................[ACTION]
ISSUE: The VCEM profile is assigned but there is no
corresponding VC profile.
RESOLUTION: The VCEM profile will be unassigned.
Unassign VCEM profile TC2a-net01_13cce2b6165......................[ACTION]
ISSUE: The VCEM profile is assigned but there is no
corresponding VC profile.
RESOLUTION: The VCEM profile will be unassigned.
Unassign VCEM profile TC3phy-net01_13cce3f3545....................[ACTION]
ISSUE: The VCEM profile is assigned but there is no
corresponding VC profile.
RESOLUTION: The VCEM profile will be unassigned.
Unassign VCEM profile TC7phy-net01_13cce5e067b....................[ACTION]
ISSUE: The VCEM profile is assigned but there is no
corresponding VC profile.
RESOLUTION: The VCEM profile will be unassigned.
Mark VC profile TC5phy-net01_13cd4016e90 addresses external:
50:01:43:80:02:A3:00:33, 50:01:43:80:02:A3:00:32,
50:01:43:80:02:A3:00:37, 50:01:43:80:02:A3:00:36,
00-21-5A-9B-00-28, 00-21-5A-9B-00-2A, 00-21-5A-9B-00-29,
00-21-5A-9B-00-2B.................................................[ACTION]
ISSUE: The addresses used by the VC profile are either not
assigned to a corresponding VCEM profile for the same
domain or the VCEM profile is unassigned.
RESOLUTION: The addresses will be marked EXTERNAL.
Mark VC profile TC4phy-net01_13cd420e192 addresses external:
50:01:43:80:02:A3:00:43, 50:01:43:80:02:A3:00:42,
50:01:43:80:02:A3:00:45, 50:01:43:80:02:A3:00:44,
00-21-5A-9B-00-34, 00-21-5A-9B-00-36, 00-21-5A-9B-00-35,
00-21-5A-9B-00-37.................................................[ACTION]
ISSUE: The addresses used by the VC profile are either not
assigned to a corresponding VCEM profile for the same
domain or the VCEM profile is unassigned.
RESOLUTION: The addresses will be marked EXTERNAL.
Mark VC profile TC8phy-net01_13cd8ff7a90 addresses external:
50:01:43:80:02:A3:00:51, 50:01:43:80:02:A3:00:50,
50:01:43:80:02:A3:00:55, 50:01:43:80:02:A3:00:54,
00-21-5A-9B-00-20, 00-21-5A-9B-00-22, 00-21-5A-9B-00-21,
00-21-5A-9B-00-23.................................................[ACTION]
ISSUE: The addresses used by the VC profile are either not
assigned to a corresponding VCEM profile for the same
domain or the VCEM profile is unassigned.
RESOLUTION: The addresses will be marked EXTERNAL.
44