Backing up and Restoring HP Insight Management 7.0 Central Management Server (Windows)

92
The mxsync tool fails if HP Storage Provisioning Manager is not installed. If HP Storage
Provisioning Manager is not installed, the Logical servers and associated SAN-based storage
section of the mxsync tool will fail.
Here is an example of the mxsync output when HP Storage Provisioning Manager is not
installed:
Workaround The mxsync command prevents the Administrator from exiting the Logical
servers and associated SAN-based storage section until it can complete each step without
error. If SPM is not installed on your CMS, you will need to perform the following steps to get
around this issue:
1. Exit mxsync by responding ”n” when asked if you would like to repeat this phase.
2. Re-run mxsync using the c –e options. For each analysis phase, you will be asked if
you would like to perform this analysis phase. Respond ”n” to skip each section that you
have already completed and to skip the phases of the Logical servers and associated
SAN-based storage section.
3. Manually start the following services from the Windows Services interface:
a. HP Extensible Storage & Server Adapter
b. HP Logical Server Automation
4. Log in to the SIM browser and run a logical server refresh by selecting HP Matrix OE
visualizationfrom the Tools menu in Systems Insight Manager. Select Logical Servers
Refresh… from the Tools menu in Matrix OE. Select all of the refresh options (except
Change Logical Server Associations), click the Refresh button, then wait for the refresh
operation to complete. You can check status of the refresh jobs by selecting Logical
Server Job Status… from the Report menu in Matrix OE.
5. Complete the remaining synchronization sections and phases of mxsync.
+--------------------------------------------------+
| Section 3 of 5 |
| Logical servers and associated SAN-based storage |
+--------------------------------------------------+
Refresh logical servers and associated SAN-based storage.
**** Analysis: HP Storage Provisioning Manager Resources ****
**** Section 3 of 5, phase 1 of 3 ****
Analyze and, if necessary, recommend actions for synchronizing the state of HP
Storage Provisioning Manager storage volumes.
An unexpected exception was encountered...............................[ERROR]
ERROR: The analysis step failed with the following exception:
java.lang.Exception: .
Analysis summary:
1 check performed
0 actions needed
0 actions require input
0 advisories
1 error
Analysis failed. A successful analysis is necessary, before executing
synchronization actions. You can choose to repeat the analysis or stop the
synchronization process. If the synchronization process is stopped, it can be
restarted later.
>>> Would you like to repeat this synchronization phase? (Y/N):