Backing up and Restoring HP Insight Management 7.0 Central Management Server (Windows)

83
Note:
If a VC profile was unassigned when the failure occurred, the VC
profile definition
c. Use the Virtual Connect Manager command line utility to release the external
manager lock. For details about releasing the external manager lock, see the HP
Virtual Connect Enterprise Manager User Guide.
d. Create the VC Domain Group from VCEM with the exact same settings as before.
e. Add the same VC Domains to the VC Domain Group as before.
f. If you have VC-based logical servers and storage pool entries in the portability
group associated with this VC Domain Group, you will need to perform an LSM
refresh. Go to HP Matrix OE visualizationfrom the Tools menu in Systems Insight
Manager. Select Logical Servers Refresh… from the Tools menu in the Virtualization
Manager. Mark Virtual Connect Enterprise Manager (VCEM) and the Change
Logical Server Associations boxes and provide the old and new Domain Group
names. Then click Refresh.