Backing up and Restoring HP Insight Management 7.0 Central Management Server (Windows)

65
Started analysis of storage volumes that are not allocated to a catalog-based
SPE, but are presented to a WWN address within the range managed by VCEM.
Checking profile : BR-C1-N1
Checking profile : BR-C1-N2
Checking profile : BR-C2-N1
Checking profile : BR-C2-N2
Checking profile : ESX_Host2
Checking profile : VCS101_12744828a5d
Checking profile : VCS301_1274f374699
Checking profile : VCS401_1274506e27d
Checking profile : vsels_LS1_VC_TEST
Checking profile : vsels_LS3_VC_TEST
Checking profile : vsels_LS4_VC_TEST
Checking \Virtual Disks\Sins_spm\Volume4
Delete storage volume "\Virtual Disks\Sins_spm\Volume4" in array ""
from SPM catalog......................................................[INPUT]
ISSUE: Storage volume "\Virtual Disks\Sins_spm\Volume4" is
marked as available in SPM. However Server WWN
50:01:43:80:02:A3:00:24 (VCEM, IN_USE) LUN 1 is
presented to storage volume "\Virtual
Disks\Sins_spm\Volume4 " in storage array "" and
assigned to VC Profile vsels_LS4_VC_TEST.
RESOLUTION: Delete storage volume "\Virtual
Disks\Sins_spm\Volume4" in storage array "" from the
SPM catalog. This is necessary to avoid the storage
volume from being reassigned to another resource.
This can occur if, as a post-backup activity the
storage volume was added to a newly created SPE and
the SPE was associated to a logical server. [ID001]
Checking \Virtual Disks\Sins_spm\Volume8
Add storage volume "\Virtual Disks\Sins_spm\Volume8" to SPE "spe7"....[INPUT]
ISSUE: Server WWN 50:01:43:80:02:A3:00:14 (LSA, IN_USE) LUN
1 is presented to storage volume "\Virtual
Disks\Sins_spm\Volume8" in storage array "". Storage
volume "\Virtual Disks\Sins_spm\Volume8" is available
in the SPM Catalog. However WWN
50:01:43:80:02:A3:00:14 is assigned to storage pool
entry "spe7".
RESOLUTION: Add storage volume "\Virtual Disks\Sins_spm\Volume8"
to SPE "spe7" to resolve the inconsistency. The
"Quarantine" checkbox must be unchecked for the
volume, the owning storage pool, and array in the SPM
GUI to perform this operation. Note: Storage volumes
must be re-added to the SPE in LUN order. [ID004]
Checking profile : BR-C1-N1
Checking profile : BR-C1-N2
Checking profile : BR-C2-N1
Checking profile : BR-C2-N2
Checking profile : ESX_Host2
Checking profile : VCS101_12744828a5d
Checking profile : VCS301_1274f374699
Checking profile : VCS401_1274506e27d
Checking profile : vsels_LS1_VC_TEST
Checking profile : vsels_LS2_VC_TEST
Checking \Virtual Disks\Sins_spm\Volume2
Delete storage volume "\Virtual Disks\Sins_spm\Volume2 " in array ""
from SPM catalog......................................................[INPUT]
ISSUE: Storage volume "\Virtual Disks\Sins_spm\Volume2" is
marked as available in SPM. However Server WWN
50:01:43:80:02:A3:00:2A (VCEM, IN_USE) LUN 1 is
presented to storage volume "\Virtual
Disks\Sins_spm\Volume2" in storage array "" and
assigned to VC Profile vsels_LS2_VC_TEST