Backing up and Restoring HP Insight Management 7.0 Central Management Server (Windows)
64
For the sample run, the results of the analysis by the lsmanalyzer tool are listed below.
lsmAnalyzer version 7.0.0.89215 started 1/19/12 6:12 AM
ADVISORY: The lsmAnalyzer tool may report transient inconsistencies
if operations are in progress while the analysis is
performed. If unexpected issues are identified, run the
analysis again after the operations have completed.
Started analysis of storage volumes allocated to catalog-based SPEs.
Checking spe9............................................................[OK]
Checking spe5............................................................[OK]
Checking spe6............................................................[OK]
Checking spe2............................................................[OK]
Checking spe7
Remove storage volume "Existing 5.000 GiB volume '\Virtual
Disks\Sins_spm\Volume7' in pool '\Disk Groups\Default Disk Group'
on array 'CH93_EVA4400'" from SPE "spe7"..............................[INPUT]
ISSUE: Server WWN 50:01:43:80:02:A3:00:14 (LSA, IN_USE) LUN
1 is assigned to storage volume "Existing 5.000 GiB
volume '\Virtual Disks\Sins_spm\Volume7' in pool
'\Disk Groups\Default Disk Group' on array
'CH93_EVA4400'" in storage pool entry "spe7". However
the WWN 50:01:43:80:02:A3:00:14 LUN 1 is presented to
storage volume "\Virtual Disks\Sins_spm\Volume8" in
storage array "". This can occur if, as a post-backup
activity, the storage volume was removed from the SPE
and replaced with a different storage volume.
RESOLUTION: Remove storage volume "Existing 5.000 GiB volume
'\Virtual Disks\Sins_spm\Volume7' in pool '\Disk
Groups\Default Disk Group' on array 'CH93_EVA4400'"
from SPE "spe7" to resolve the inconsistency. [ID003]
Completed analysis of storage volumes allocated to catalog-based SPEs.
Analysis summary:
5 checks performed
1 action needed
1 action requires input
0 errors
Analysis completed successfully. All issues identified in the above section
should be resolved before proceeding to the next section.
Verifying the recovery mode state of the "HP Storage Provisioning Manager
Service".
The "HP Storage Provisioning Manager Service" is not running in
recovery mode............................................................[OK]
Execution summary:
1 action performed
0 advisories
0 errors
>>> Please press [ENTER] to continue: