User's Guide
Configuring HyperFabric
Configuring HyperFabric with ServiceGuard
Chapter 4
80
Figure 4-5 When All HyperFabric Adapters Fail
Configuring HyperFabric with the ServiceGuard Resource Monitor
You can configure the HyperFabric Resource Monitor with ServiceGuard in either of
these ways:
• Editing an ASCII file.
• Using the SMH GUI.
For more details, please see the manual Using EMS HA Monitors.
NOTE You should configure HyperFabric with ServiceGuard before running the clic_start
command or using SMH to start HyperFabric.
Configuring ServiceGuard with HyperFabric Using the ASCII File
When using the ServiceGuard commands (for example, cmapplyconf) to specify the use of
the HyperFabric Resource Monitor, the section of the package ASCII configuration file
that has the keyword RESOURCE_NAME must be uncommented and set to the following
values:
RESOURCE_NAME /net/interfaces/clic/status
RESOURCE_POLLING_INTERVAL 10
HF
adapter 1
HF
adapter 0
HF
adapter 0
switch 0
HF
switch 1
HF
Ethernet Port
HF
adapter 1
Ethernet Port
Ethernet Heartbeat LAN 1
Ethernet Heartbeat LAN 0
node A
node B
Package
B
A
HyperFabric
Resource
HyperFabric
Resource
Failed
Packages
failover to
Node B
Active
Package