Administrator's Guide
Configuring HyperFabric
Configuring HMP for Transparent Local Failover Support
Chapter 4102
Configuring HMP for Transparent Local Failover
Support - Using SAM
To use SAM to configure HMP for Local Failover Support, complete the
following steps:
Step 1. Start SAM.
Step 2. Select the “Networking and Communications” area.
Step 3. Select “HyperFabric.”
All HyperFabric adapters installed in the system are listed; installed
adapters that are not yet configured show Not Configured in the
“Status” field. Before proceeding to the next step, configure all the
available adapters.
Step 4. Pull down the "Actions" menu and select "Configure Local Failover for
HMP". SAM now verifies the following:
• If not all the adapters are configured
• If the number of adapters configured are odd
• If “Interoperability Enabled” is set to YES
If any of the above conditions is true, then SAM displays an
appropriate error message. Otherwise, the “Configure Local Failover
for HMP” window pops up.
Step 5. In this window, specify the configured adapters for each card pair and
press OK.
On pressing OK, SAM verifies the following:
• If HyperFabric subsystem is not running on the machine
• If all card pairs are not configured
• If you have chosen the same adapter for different card pairs
If any of the above conditions is true, SAM displays an appropriate
error message. Otherwise, the
/etc/rc.config.d/clic_global_conf file is updated with
information about the configured card pairs. If Card-Pair 0 comprises