Installation Manual
61
Field Descri
p
tion
State
Fan state:
• Normal—The fan is operating correctly.
• Absent—The fan is not in position.
• Fault—The fan has failed.
Displaying the power module operating status
Use the display power command to display the power module operating status.
<Sysname> display power
System Power Total : 650 watts
System Power Used : 275 watts
System Power Usable : 375 watts
Power No. Type Watts State ID
---------------------------------------------
1 N/A N/A Absent N/A
2 AC 650 Normal 0
Table 17 Command output
Field Descri
p
tion
System Power Total Total power provided by the power modules.
System Power Used Power in use.
System Power Usable Power available for use.
Power No. Slot number of the power module.
Type
Power module type:
• AC—AC power modules.
• DC—DC power modules.
Watts Power provided by the power module.
ID Power module ID.
State
Power module state:
• Normal—The power module is operating correctly.
• Absent—The power module is not in position.
• Fault—The power module has failed.
Displaying the alarming thresholds of a card
Use the display environment command to display the temperature information and alarming thresholds
of a card.
<Sysname> display environment
Temperature information (degree centigrade):
----------------------------------------------------------
SlotNo Temperature Lower limit Upper limit