Installation Manual

101
Item Remarks
Hot swapping Supported
NOTE:
For a combo interface, the default operating port is the copper port. You can use either the copper por
t
or the fiber port. To switch between the copper and fiber ports, use the combo enable { copper | fiber }
command in interface view. For more information about the combo enable { copper | fiber } command,
see
HP HSR6800 Routers
Interface Command Reference
.
Use transceiver modules for the fiber ports provided by HP only. The router mi
g
ht be incompatible with
transceiver modules from other manufacturers. The system generates an alarm when a transceiver
module from another manufacturer is installed.
FIP-310 combo interface specifications
Specification of combo interfaces on the FIP-310 is the same as FIP-110. For more information, see Table
34 and Table 35.
T
ransceiver modules for the FIP-310 are the same as the FIP-110. For more information, see Table 36.
FIP-310 10 Gbps Ethernet port specifications
Table 37 FIP-310 10 Gbps Ethernet port specifications
Specification Description
Connector type LC
Transceiver module type SFP+
Interface standards 802.3ae
Transmission
power
Type
Short-haul
multi-mode
(850 nm)
Mid-haul
single-mode
(1310 nm)
Long haul
(1310 nm)
Long haul
(1550 nm)
Super long
haul (1550
nm)
Minimum –7.3 dBm –6.5 dBm –8.2 dBm –4.7 dBm 0 dBm
Maximum –1 dBm 0.5 dBm 0.5 dBm 4 dBm 4 dBm
Receive sensitivity –7.5 dBm –6.5 dBm –10.3 dBm –11.3 dBm –24 dBm
Central wavelength 850 nm 1310 nm 1310 nm 1550 nm 1550 nm
Fiber type
50/125 m
and
65.5/125
m
multi-mode
fiber
50/125 m
and
65.5/125 m
multi-mode
fiber
9/125 m
single-mode
fiber
9/125 m
single-mode
fiber
9/125 m
single-mode
fiber
Operating mode 10 Gbps (full duplex)
Maximum interface modules provided by FIP-310 in full configuration
FIP/Interface module SR6604-
X
SR6608-
X
SR6616-
X
FIP-310 2 4 8