HP StorageWorks XP Disk Array Mainframe Host Attachment and Operations Guide XP24000, XP20000 (A5951 - 96151, September 2007)

Full-duplex bi-directional data transfers
Multiple I/O processes
Allows small and large data transfers to be transmitted at the same time
High-bandwidth transfer (up to 4 Gbps)
Greater throughput rates over longer distances than ESCON
Lowered interlock between the disk controller and channel
Executing pipeline CCW
FICON Physical Specifications
The following table compares the physical specifications between ESCON and FICON.
Table 3 Comparing ESCON and FICON Physical Specifications
FICONESCONItem
ANSI FC-PHESCONPhysical Interface
ANSI FC-SB-2/FC-SB-3/PC-PI-2ESCONLogical Interface
1 Gbps / 2 Gbps / 4 Gbps, bidirectional200 Mbps, unidirectionalBandwidth and direction
Single Mode/9umMulti Mode/62.5umCable
Multi Mode/50 or 62.5um
Distance
Single Mode/9umLong wave
10 km, 20 km (with RPQ)
Multi Mode/ 62.5um
300m(1Gbps)/150m(2Gbps)/75m(4Gbps)
3 kmShort wave
Multi Mode/ 50um
500m(1Gbps)/300m(2Gbps)/150m(4Gbps)
LC-duplex (see the following figure)ESCON ConnectorConnector
Point-to-Point and Switched Point-to-PointPoint-to-Point and Switched
Point-to-Point
Topologies
XP Disk Array Mainframe Host Attachment and Operations Guide 25