HP StorageWorks Disk Array XP operating system configuration guide for HP-UX XP24000, XP12000, XP10000, SVS200, v01 (A5951-96018, June 2007)

In Command View XP Advanced Edition Software, LUN mapping includes:
Configuring ports
Creating storage groups
Mapping volumes and WWN/host access permissions to the storage groups
For details see the HP StorageWorks XP LUN Manager User’s Guide or the HP StorageWorks
Command View XP Advanced Edition Software Device Manager Web Client User’s Guide. Note the
LUNs and their ports, WWNs, nicknames, and LDEVs for later use in verifying host and device
configuration.
Verifying HBA installation
After configuring the ports on the disk array, verify that the HBAs are installed properly.
Use the ioscan –fcommand, and verify that the rows shown in the example are displayed. If these
rows are not displayed, check the host adapter installation (hardware and driver installation) or the
host configuration.
Example
# ioscan –f
Class I H/W Path Driver S/W State H/W Type Description
...
fc 0 8/12 fcT1 CLAIMED INTERFACE HP Fibre ...
lan 1 8/12.5 fcT1_cntl CLAIMED INTERFACE HP Fibre ...
fcp 0 8/12.8 fcp CLAIMED INTERFACE FCP Proto...
ext bus 2 8/12.8.0.255.0 fcpdev CLAIMED INTERFACE FCP Devic...
Verifying device recognition
Verify that the HP-UX system recognizes the new devices on the disk array.
If the SCSI paths were defined after the system is powered on, you must halt and restart the system
to allow the system to recognize the new devices.
XP Disk Array Configuration Guide for HP-UX 19