HP StorageWorks XP Disk Array Mainframe Host Attachment and Operations Guide (A5951-96154, September 2010)
11. On the Add Device panel, enter the following, and then press Enter:
• Device number
• Number of devices
• Device type: 3390, 3390B for PAV base device, or 3390A for PAV alias device
Goto Filter Backup Query Help
.-------------------------------- Add Device ---------------------------------.
| |
| |
| Specify or revise the following values. |
| |
| Device number . . . . . . . . 8000 (0000 - FFFF) |
| Number of devices . . . . . . 128 |
| Device type . . . . . . . . . 3390B________ + |
| |
| Serial number . . . . . . . . __________ |
| Description . . . . . . . . . 3390 Base addresses 8000-807F__ |
| |
| Volume serial number . . . . . ______ (for DASD) |
| |
| Connected to CUs . . 8000 ____ ____ ____ ____ ____ ____ ____ + |
| |
| |
| F1=Help F2=Split F3=Exit F4=Prompt F5=Reset F9=Swap |
| F12=Cancel |
'-----------------------------------------------------------------------------'
12. On the Device / Processor Definition panel, add this device to a specific Processor/System-ID
combination by inputting an S next to the Processor and then press Enter.
.-------------------- Device / Processor Definition --------------------.
| Row 1 of 1 |
| Command ===> _____________________________________ Scroll ===> PAGE |
| |
| Select processors to change device/processor definitions, then press |
| Enter. |
| |
| Device number . . : 8100 Number of devices . : 128 |
| Device type . . . : 3390B |
| |
| Preferred Explicit Device |
| / Processor ID UA + Time-Out STADET CHPID + Candidate List | *****
| s PROD __ No Yes __ No |
| ************************** Bottom of data *************************** |
| |
| |
| |
| |
| |
| |
| |
| F1=Help F2=Split F3=Exit F4=Prompt F5=Reset |
| F6=Previous F7=Backward F8=Forward F9=Swap F12=Cancel |
'-----------------------------------------------------------------------'
XP Disk Array Mainframe Host Attachment and Operations Guide 39