HP StorageWorks XP Disk Array Mainframe Host Attachment and Operations Guide (A5951-96154, September 2010)
UNIT=2105,CUADD=04,UNITADD=((00,256))
CNTLUNIT CUNUMBR=8600,PATH=(F9,FB,FD,FF), *
LINK=(04,**,**,05), *
UNIT=2105,CUADD=05,UNITADD=((00,256))
IODEVICE ADDRESS=(8100,064),CUNUMBR=(8100),STADET=Y,UNIT=3390B
IODEVICE ADDRESS=(8180,128),CUNUMBR=(8100),STADET=Y,UNIT=3390A*
,UNITADD=80
IODEVICE ADDRESS=(8200,064),CUNUMBR=(8200),STADET=Y,UNIT=3390B
IODEVICE ADDRESS=(8280,128),CUNUMBR=(8200),STADET=Y,UNIT=3390A*
,UNITADD=80
IODEVICE ADDRESS=(8300,064),CUNUMBR=(8300),STADET=Y,UNIT=3390B
IODEVICE ADDRESS=(8380,128),CUNUMBR=(8300),STADET=Y,UNIT=3390A*
,UNITADD=80
IODEVICE ADDRESS=(8400,064),CUNUMBR=(8400),STADET=Y,UNIT=3390B
IODEVICE ADDRESS=(8480,128),CUNUMBR=(8400),STADET=Y,UNIT=3390A*
,UNITADD=80
IODEVICE ADDRESS=(8500,128),CUNUMBR=(8500),STADET=Y,UNIT=3390B
IODEVICE ADDRESS=(8580,128),CUNUMBR=(8500),STADET=Y,UNIT=3390A
IODEVICE ADDRESS=(8600,128),CUNUMBR=(8600),STADET=Y,UNIT=3390B
IODEVICE ADDRESS=(8680,128),CUNUMBR=(8600),STADET=Y,UNIT=3390A
The following example shows a sample IOCP hardware definition for a storage system configured
with:
• 3990 ID
• Two (2) LPARs called PROD and TEST sharing 4 ExSA (ESCON) channels connected over 2 ESCDs
to the storage system
• Each switch has ports C0 and C1 attached to the storage system
• Four (4) control unit images (0, 1, 2, 3) with 256 LVIs per control unit
• Two (2) CU statements per control unit image
• To protect data integrity due to multiple operating systems sharing these volumes, these devices
require FEATURE=SHARED.
CHPID PATH=(B0,B1),TYPE=CNC,PARTITION=(PROD,TEST,SHR),SWITCH=01
CHPID PATH=(B2,B3),TYPE=CNC,PARTITION=(PROD,TEST,SHR),SWITCH=02
CNTLUNIT CUNUMBR=A000,PATH=(B0,B1),UNITADD=((00,256)),LINK=(C0,C1),CUADD=0,UNIT=3990
CNTLUNIT CUNUMBR=A001,PATH=(B2,B3),UNITADD=((00,256)),LINK=(C0,C1),CUADD=0,UNIT=3990
CNTLUNIT CUNUMBR=A100,PATH=(B0,B1),UNITADD=((00,256)),LINK=(C0,C1),CUADD=1,UNIT=3990
CNTLUNIT CUNUMBR=A101,PATH=(B2,B3),UNITADD=((00,256)),LINK=(C0,C1),CUADD=1,UNIT=3990
CNTLUNIT CUNUMBR=A200,PATH=(B0,B1),UNITADD=((00,256)),LINK=(C0,C1),CUADD=2,UNIT=3990
CNTLUNIT CUNUMBR=A201,PATH=(B2,B3),UNITADD=((00,256)),LINK=(C0,C1),CUADD=2,UNIT=3990
CNTLUNIT CUNUMBR=A300,PATH=(B0,B1),UNITADD=((00,256)),LINK=(C0,C1),CUADD=3,UNIT=3990
CNTLUNIT CUNUMBR=A301,PATH=(B2,B3),UNITADD=((00,256)),LINK=(C0,C1),CUADD=3,UNIT=3990
IODEVICE ADDRESS=(A000,256),CUNUMBR=(A000,A001),UNIT=3390,FEATURE=SHARED
IODEVICE ADDRESS=(A100,256),CUNUMBR=(A100,A101),UNIT=3390,FEATURE=SHARED
IODEVICE ADDRESS=(A200,256),CUNUMBR=(A200,A201),UNIT=3390,FEATURE=SHARED
IODEVICE ADDRESS=(A300,256),CUNUMBR=(A300,A301),UNIT=3390,FEATURE=SHARED
The following example shows a sample IOCP hardware definition for a storage system with:
• 2105 ID
• Eight (8) ExSA (ESCON) channels directly connected to the storage system
• Four (4) control units images with 256 LVIs per control unit
• One (1) CU statement per control unit image
• One hundred twenty-eight (128) 3390 base addresses per CU 0 and 1
• One hundred twenty-eight (128) 3390 alias addresses per CU 0 and 1
• Sixty-four (64) 3390 base addresses in CU 2
• One hundred ninety-two (192) 3390 alias addresses in CU 2
• One hundred twenty-eight (128) 3390 addresses in CU 3
• Sixty-four (64) 3390 base addresses per CU 3
• Sixty-four (64) 3390 alias addresses per CU 3
XP Disk Array Mainframe Host Attachment and Operations Guide 31