HP StorageWorks Disk Array XP operating system configuration guide for Windows 2000/2003 XP24000, XP12000, XP10000, SVS200, v01 (A5951-96195, June 2007)
CAUTION:
The correct host mode must be set for all new installations (newly connected ports) to Windows 2000/2003
hosts. Do not select a mode other than 2C or 0C for Windows 2000/2003. Changing a host mode after
the host has been connected is disruptive and requires the server to be rebooted.
When a new host group is added, additional host group modes (options) may be configured. The
storage administrator must verify if an additional host group mode is required for the host group.
The following host group modes (options) are available for Windows 2000/2003:
Table 4 Host group modes (options)
DefaultFunctionHost Group
Mode
InactiveVERITAS DBE+RAC Database Edition/Advanced Cluster for Real
Application Clusters or VERITASĀ® Cluster Server 4.0 with I/O
fencing is used.
2
(Windows
2003 only)
InactiveParameter Setting Failure for TPRLO
When using the Emulex HBA in the Windows environment, the
parameter setting for TPRLO failed. After receiving TPRLO and
FCP_CMD, respectively. PRLO will respond when
HostMode=0x0C/0x2C and HostModeOption=0x06. (MAIN
Ver.50-03-14-00/00 and later)
6
CAUTION:
Changing host group modes for ports where servers are already installed and configured is disruptive and
requires the server to be rebooted.
XP Disk Array Configuration Guide for Windows 2000/2003 15