1266 : [RMSRA20][Time]: [failover_chk] : The output of “Command line” is missing.
Cause: Could not find the correct format in the output of the “Command line” command via failover.
Action: Confirm that the RAID Manager corrected version is supported in RM SRA.
1256 : 1257 : 1260 [RMSRA20][Time]: [testFailover_chk] : “ Command line” GRP = ,
L/R = , P/S = , Status = , CTG =
Cause: The pair status of a target volume specified with testFailover is inappropriate ('SMPL'
or 'PVOL' or 'NOT PAIR').
Action: Confirm that volume status is appropriate (BC is 'SVOL' and 'PAIR') using the pairdisplay
command.
1266 : [RMSRA20][Time]: [testfailover_chk] : The output of “Command line” is missing
Cause: Could not find the correct format in the output of “Command line” command via
testFailover.
Action:Confirm that the RAID Manager corrected version is supported in RM SRA.
1272 : [RMSRA20][Time]: [fov_group_exe] : invalid arrayId (…).
Cause: A parameter in XML (naming) was input from SRM to the SRA, but it could not fin the correct
array ID.
Action: Confirm that SRM was passed an array ID parameter in XML (failover) from the SRM log
message.
1265 : [RMSRA20][Time]: [failover_chk] : Unknown LWWN.
Cause: Could not find the LUN WWN in the output of the pairdisplay –few command with
checkfailover/failover.
Action: Confirm that the RAID Manager corrected version is supported in RM SRA.
1265 : [RMSRA20][Time]: [testfailover_chk] : Unknown LWWN
Cause: Could not find the LUN WWN in the output of the pairdisplay –few command with
checktestfailover/testfailover.
Action: Confirm that the RAID Manager corrected version is supported in RM SRA.
Error codes for multiple errors
RM SRA defines an error code by an OR flag of 32 bits so that you can identify multiple errors in
the transaction from XML data strings.
For example: [RMSRA20][Sun Aug 3 16:25:56 2008]: [command_main] : 'testFailover_start'
failed with error(0x00002000) on arrayId(64015).
Table 6 (page 49) explains these error codes.
Table 6 Error codes
ReasonError bitsError codes
XX : exit code returned from RAID Manager command See the RAID
Manager command error code in the RAID Manager User Guide.
0x000000XX1200-1255
The volume is in the incorrect state (SMPL) for this operation.0x000001001256
The volume is inappropriate property as PVOL.0x000002001257
The volume is inappropriate property as SVOL.0x000004001258
Undefined.0x000008001259
Error Messages on SRM log files 49