HP StorageWorks XP Disk Array Mainframe Host Attachment and Operations Guide XP24000, XP20000 (A5951 - 96151, September 2007)
IMPORTANT:
ESCON interfaces support 1024 unit addresses per channel and up to 4096 devices for each set of 16
CU images using CUADD=0 through CUADD=F in the CNTLUNIT statement. ESCON channel interfaces
can be assigned to access individual groups of 16 control unit images.
The following example shows a sample IOCP definition for a storage system configured with:
• 2105 ID
• Four FICON channel paths. Two channels paths are connected to a FICON switch. Two channel
paths are directly connected to the storage system.
• Six control unit images (00, 01, 02, 03, 04, 05) with 256 LVIs per control unit
• 64 base addresses and 128 alias addresses per CU 00, 01, 02, and 03
• 128 base addresses and 128 alias addresses per CU 04 and 05
******************************************************
**** Sample FICON CHPID / CNTLUNIT and IODEVICE ******
******************************************************
CHPID PATH=(F9),TYPE=FC,SWITCH=07
CHPID PATH=(FB),TYPE=FC
CHPID PATH=(FD),TYPE=FC
CHPID PATH=(FF),TYPE=FC,SWITCH=07 *
CNTLUNIT CUNUMBR=8100,PATH=(F9,FB,FD,FF), *
LINK=(04,**,**,05), *
UNIT=2105,CUADD=00,UNITADD=((00,256))
CNTLUNIT CUNUMBR=8200,PATH=(F9,FB,FD,FF), *
LINK=(04,**,**,05), *
UNIT=2105,CUADD=01,UNITADD=((00,256))
CNTLUNIT CUNUMBR=8300,PATH=(F9,FB,FD,FF), *
LINK=(04,**,**,05), *
UNIT=2105,CUADD=02,UNITADD=((00,256))
CNTLUNIT CUNUMBR=8400,PATH=(F9,FB,FD,FF), *
LINK=(04,**,**,05), *
UNIT=2105,CUADD=03,UNITADD=((00,256))
CNTLUNIT CUNUMBR=8500,PATH=(F9,FB,FD,FF), *
LINK=(04,**,**,05), *
UNIT=2105,CUADD=04,UNITADD=((00,256))
CNTLUNIT CUNUMBR=8600,PATH=(F9,FB,FD,FF), *
LINK=(04,**,**,05), *
UNIT=2105,CUADD=05,UNITADD=((00,256))
IODEVICE ADDRESS=(8100,064),CUNUMBR=(8100),STADET=Y,UNIT=3390B
IODEVICE ADDRESS=(8180,128),CUNUMBR=(8100),STADET=Y,UNIT=3390A*
,UNITADD=80
IODEVICE ADDRESS=(8200,064),CUNUMBR=(8200),STADET=Y,UNIT=3390B
IODEVICE ADDRESS=(8280,128),CUNUMBR=(8200),STADET=Y,UNIT=3390A*
,UNITADD=80
IODEVICE ADDRESS=(8300,064),CUNUMBR=(8300),STADET=Y,UNIT=3390B
IODEVICE ADDRESS=(8380,128),CUNUMBR=(8300),STADET=Y,UNIT=3390A*
,UNITADD=80
IODEVICE ADDRESS=(8400,064),CUNUMBR=(8400),STADET=Y,UNIT=3390B
IODEVICE ADDRESS=(8480,128),CUNUMBR=(8400),STADET=Y,UNIT=3390A*
,UNITADD=80
IODEVICE ADDRESS=(8500,128),CUNUMBR=(8500),STADET=Y,UNIT=3390B
IODEVICE ADDRESS=(8580,128),CUNUMBR=(8500),STADET=Y,UNIT=3390A
IODEVICE ADDRESS=(8600,128),CUNUMBR=(8600),STADET=Y,UNIT=3390B
IODEVICE ADDRESS=(8680,128),CUNUMBR=(8600),STADET=Y,UNIT=3390A
NOTE:
FICON channel interfaces support a maximum of 16,384 device addresses. Multiple groups of FICON
channels may be used to access the maximum of 65,280 devices that can be configured using a maximum
of 255 control unit images (CUADD 00 to FE).
z/OS Operations42