HP StorageWorks XP Disk Array Mainframe Host Attachment and Operations Guide (A5951-96154, September 2010)

Return CodeStorage SystemArgumentCommand
CC = 0, ALT information not displayed.RAMAC
NOPRESERVE,
NOSKIP,
CC = 0XP disk arrayNOCHECK
CC = 12 Invalid parameter(s) for device type.RAMAC
ALLTRACKS,
ASSIGN,
RECLAIM
In case of PRESERVE: CC = 12
In case of NO PRESERVE: CC = 0.
XP disk array
CC = 0 (but not recommended by IBM).RAMAC
SETMODE
(3390)
INSTALL
CC = 0XP disk array
CC = 12, Invalid parameter(s) for device type.RAMAC
SETMODE
(3380)
CC = 12, Function not supported for
nonsynchronous DASD.
XP disk array
CC = 0RAMACANALYZE
CC = 0XP disk array
CC = 0RAMACBUILDX
CC = 0XP disk array
CC = 12 Device not supported for the specified
function.
RAMACREFRESHREVAL
CC = 12, F/M = 04 (EC=66BB) Error, not a
data check. Processing terminated.
XP disk array
CC = 0, Data/Nodata parameter not allowed.RAMACDATA, NODATA
CC=0XP disk array
CC = 0, ALT information not displayed.RAMACCONTROL
CC = 0, ALT information not displayed.XP disk array
CC = 0, ALT information not displayed.RAMACINIT
CC = 0XP disk array
CC = 0, ALT information not displayed.RAMACREFORMAT
CC=0XP disk array
Mainframe operations44