HP XP P9500 Disk Array Configuration Guide (AV400-96496, May 2014)

For example, enter the following command to change the queue depth for the device hdisk3:
# chdev l hdisk3 a queue_depth='2'
4. Verify that the parameters for all devices were successfully changed.
For example, enter the following command to verify the parameter change for the device
hdisk3:
# lsattr E l hdisk3
5. Repeat these steps for each OPEN-x device on the disk array.
TIP: The lsattr command also shows useful information, such as LUN ID of the mapped
LDEV, worldwide name of the disk array FC port, and N-Port ID.
Another useful command for determining the slot position and port worldwide name of the
FCA is the lscfg v l hdiskx command.
Changing the device parameters using SMIT
1. Start SMIT. (Optional) For an ASCII session, use the smit C command.
2. Select Devices.
Example
System Management
Move cursor to desired item and press Enter.
Software Installation and Maintenance
Software License Management
Devices
System Storage Management (Physical & Logical Storage)
Security & Users
Communications Applications and Services
Print Spooling
Problem Determination
Performance & Resource Scheduling
System Environments
Processes & Subsystems
Applications
Using SMIT (information only)
3. Select Fixed Disk.
4. Select Change/Show Characteristics of a Disk.
5. Select the desired device from the Disk menu.
The Change/Show Characteristics of a Disk screen for that device is displayed.
6. Enter the correct values for the read/write timeout value, queue depth, and queue type
parameters. Press Enter to complete the parameter changes.
Example
Change/Show Characteristics of a Disk
Type or select values in entry fields.
Press Enter AFTER making all desired changes.
[MORE...4]
Status
Location
Parent adapter
Connection address
Physical volume IDENTIFIER
ASSIGN physical volume identifier no
Queue DEPTH [2]
Queuing TYPE [simple]
90 IBM AIX