HP XP P9000 Smart Manager for Mainframe Messages (TB589-96003, July 2013)
Explanation and recommended actionsMessage textMessage ID
The combination of the copy groups is one of the following:
• The serial numbers of the primary site storage systems are the
same; the serial numbers of the secondary site storage systems
are different; and copy pairs with the same consistency group ID
exist.
• The serial numbers of the primary site storage systems are different;
the serial numbers of the secondary site storage systems are the
same; and copy pairs with the same sub consistency group ID
exist.
If the copy type is Continuous Access Journal, these combinations are
not supported.
dd-name
dd name of the CSV file where the error was detected
rec#
Number of the line in the file identified by dd-name where the
error was detected
A specific combination of a storage
system serial number and a C/T
group ID is used for multiple CAJ
Copy Groups: dd-name: rec#
YKJ212E TSO RC=32
The volume specified as the S-VOL is also specified as the S-VOL for
other copy pairs. The same volume cannot be specified as the S-VOL
for multiple copy pairs.
dd-name
dd name of the CSV file where the error was detected
rec#
Number of the line in the file identified by dd-name where the
error was detected
Secondary volume is already spe-
cified in another copy pair as a sec-
ondary device: dd-name: rec#
YKJ213E TSO RC=32
A copy pair capacity check could not be performed because the
capacity of a volume could not be acquired. A capacity check cannot
be performed in either of the following cases:
• When a volume capacity has not been acquired during a Local
Scan, Remote Scan, or NG Scan.
• When a volume is in any of the storage systems below and a
Remote Scan or NG Scan has been performed on the volume. In
this case, the capacity of the volume cannot be acquired.
- XP1024/XP128 series
- XP12000
- XP24000
A copy group definition file was created, but the settings might contain
incorrect information.
A copy pair capacity check could
not be performed because the capa-
city of a volume could not be ac-
quired.
YKJ214W TSO RC=8
The capacities of the copy pair volumes are different. A copy pair
whose P-VOL and S-VOL capacities are different cannot be defined.
To create a copy pair whose P-VOL and S-VOL capacities are different
for migration, specify NOCHECK for the CAPACITY parameter, and
execute the YKIMPORT command. For details, see HP XP P9000 for
Business Continuity Manager Software Reference Guide.
dd-name
The dd name of the CSV file where the error was detected
rec#
Number of the line in the file indicated by dd-name where the
error was detected
The capacities of the copy pair
volumes are different: dd-name:
rec#
YKJ215E TSO RC=32
Messages 95