HP XP P9000 Smart Manager for Mainframe Messages (TB589-96003, July 2013)
Explanation and recommended actionsMessage textMessage ID
BCM Monitor set the monitoring status of the copy group cgid to the
status status.
time
Message output time
This is only displayed when the output destination is SYSTSPRT.
status
• START: The monitoring status of the copy group was set to ACT-
IVE.
• STOP: The monitoring status of the copy group was set to INACT-
IVE.
time Set MONITOR=status for
Copy Group 'cgid'.
YK8047I PRT CON
BCM Monitor set CYCLETIME to the value identified by cycletime.
time
Message output time
This is only displayed when the output destination is SYSTSPRT.
time Set CYCLETIME to : cycle-
time.
YK8048I PRT CON
BCM Monitor set WAITTIMEOUT to the value identified by timeout.
time
Message output time
This is only displayed when the output destination is SYSTSPRT.
time Set WAITTIMEOUT to :
timeout.
YK8049I PRT CON
BCM Monitor set MSGLEVEL to the values identified by lvllog and
lvlcons.
time
Message output time
This is only displayed when the output destination is SYSTSPRT.
lvllog
Level of messages to be output to SYSTSPRT
lvlcons
Level of messages to be output to the console
time Set MSGLEVEL to : MSG-
LEVEL=lvllog,lvlcons.
YK8050I PRT CON
BCM Monitor resumed processing.
time
Message output time
This is only displayed when the output destination is SYSTSPRT.
time BCM Monitor resume monitor-
ing.
YK8054I PRT CON
BCM Monitor will go to sleep because the PAUSE action was executed.
Entering the WAKEUP command resumes copy group monitoring before
the sleep time of sleep-time has elapsed.
time
Message output time
This is only displayed when the output destination is SYSTSPRT.
sleep-time
Sleep duration
time BCM Monitor will pause now
for 'sleep-time' minutes.
YK8055I PRT CON