HP XP P9000 Smart Manager for Mainframe Messages (TB589-96003, July 2013)

Explanation and recommended actionsMessage textMessage ID
The main task or subtask terminated abnormally during BCM Monitor
processing. If the task cannot be recovered, BCM Monitor will stop.
Contact the center administrator.
Sxxx (hexadecimal number)
System completion code when the task terminated abnormally
Uxxxx (decimal number)
User completion code when the task terminated abnormally
module-name
Section name of the BCM Monitor module or load module name.
If the module cannot be identified, UNKNOWN is displayed. In this
case, the values of y'y'.m'm'.d'd' and bbbbbbbb are invalid.
module-creation-date
This is displayed in one of the following formats:
y'y'.m'm'.d'd': Creation date of the module identified by
module-name
y'y'/m'm'/d'd': Creation date of the module identified by
module-name
bbbbbbbb
Contents of the base register
dddd
ABENDED-MODULE: Location where ABENDED-MODULE was
called, relative to the top of the module
CALLING-MODULE: Location where CALLING-MODULE was
called, relative to the top of the module
pppppppp pppppppp
PSW during the abnormal termination
ll
Length of the command during the abnormal termination
xx
Interrupt code during the abnormal termination
BCM Monitor function abend:
code=Sxxx Uxxxx
abended-module=module-name
C-Date=module-creation-date
base=bbbbbbbb disp=dddd
[calling-module=module-name
C-Date=y'y'.m'm'.d'd'
base=bbbbbbbb disp=dddd]
PSW=pppppppp pppppppp
ILC=ll INTC=xx
Registers at time of failure
GR 00-03
contents-of-register-0
contents-of-register-1
contents-of-register-2
contents-of-register-3
GR 04-07
contents-of-register-4
contents-of-register-5
contents-of-register-6
contents-of-register-7
GR 08-11
contents-of-register-8
contents-of-register-9
contents-of-register-10
contents-of-register-11
GR 12-15
contents-of-register-12
contents-of-register-13
contents-of-register-14
contents-of-register-15
YK8028E CON
The value identified by error-type, which was specified in the
command-name command, is invalid.
error-type
label: The label name is invalid. Check the label name for AC-
TION=STOPPOINT specified in the YKMONCG file.
copy group: The copy group ID is invalid. Check the copy group
ID for CGID specified in the YKMONCG file.
The specified error-type is inval-
id: command-name.
YK8031W CON
BCM Monitor will stop at the point label.
time
Message output time
This is only displayed when the output destination is SYSTSPRT.
label
Label at which BCM Monitor stops
time BCM Monitor will stop at
STOPPOINT 'label'.
YK8040I PRT CON
Messages52