HP XP P9000 Smart Manager for Mainframe Messages (TB589-96003, July 2013)
Type of error
Error details
Error
code
OtherSMARTPATHCMDCAJCAACABC
NNNNNYYNThe RCU has its cache (one side) blocked (NVS).
C3AA
NNNNNYYNThe RCU has its cache (one side) blocked.
C3AB
NNNNNYYN
The RCU has exceeded the charging limit for the
CA or CAA program product.
C3AD
NNNNNYYN
The CA or CAA program product has not been
installed on the RCU.
C3AE
NNNNNYYN
The storage system type for the RCU is not suppor-
ted by CA or CAA, or the C/T group value for
CAA is incorrect.
C3AF
NNNNNYYN
The condition setting of the number of the Minimum
Path is incorrect.
C3B1
NNNNNYYNThe CA or CAA P-VOL is a BC pair volume.
C3B6
NNNNNYYNThe CA or CAA S-VOL is a BC pair volume.
C3B7
NNNNNYYN
A copy pair cannot be made because the specified
SSID or CU number for the RCU is not supported
for the primary and secondary site.
C3BA
NNNNNYYNThe P-VOL is online.
C3BD
NNNNNYYN
When the P-VOL of a CA or CAA copy pair is also
the S-VOL of a BC copy pair, it must be in the Split
status. Also, a reserve volume, a P-VOL in the Re-
verse Resync status, and the S-VOL for FlashCopy
cannot be specified.
C3BE
NNNNNYYN
The S-VOL of a BC copy pair or a Reserve volume
cannot be specified as the S-VOL of a CA or CAA
copy pair. Also, a P-VOL in the Reverse Resync
status and the S-VOL for FlashCopy cannot be
specified.
C3BF
NNNNNYYN
When the P-VOL of a CA or CAA copy pair is also
the S-VOL of a BC copy pair, both S-VOLs must be
a copy pair in a one-to-one combination.
C3C0
NNNNNYNNThe S-VOL is not made under the C/T group.
C3C1
NNNNNYNN
The C/T group ID specified in making a copy pair
is already in use in the S-VOL.
C3C2
NNNNNYNN
The 4MCU is already registered or made under
the subjected C/T group.
C3C3
NNNNNYNN
The option information (timer type, timeout) for an
operating (already being made a copy pair) C/T
group cannot be changed.
C3C4
Storage system sense byte information264