HP XP P9000 Smart Manager for Mainframe Messages (TB589-96003, July 2013)
Type of error
Error details
Error
code
OtherSMARTPATHCMDCAJCAACABC
NNNNNYYNThe S-VOL is not DFW ON.
C333
NNNNNYYNThe S-VOL is a CAA P-VOL.
C335
NNNNNYYNThe S-VOL has PIN data.
C336
NNNNNYYNThe S-VOL is in the Reserve status.
C337
NNNNNYYN
An intervention request has been issued for the S-
VOL (S-VOL or reserve volume of BC).
C338
NNNNNYYNThe S-VOL is in the FC status.
C339
NNNNNYYN
A copy pair cannot be made because the specified
S-VOL does not support CA.
C33A
NNNNNYYNThe S-VOL is an S-VOL of another copy pair.
C33B
NNNNNYYN
A copy pair cannot be made because the specified
S-VOL is not installed.
C33C
NNNNNYYN
An intervention request has been issued for the S-
VOL (DEV NOT READY status).
C33E
NNNNNYYNThe S-VOL is a CA or CAA pair volume.
C33F
NNNNNYYNThe P-VOL cannot be accessed.
C35C
NNNNNYYN
The condition setting for the number of the Minim-
um Path is incorrect (path problem or invalid path).
C370
NNNNNYYN
Recovery processing for cache memory or shared
memory is being performed. Wait a few minutes,
and then execute again.
C371
NNNNNYYN
Recovery processing for cache memory or shared
memory is being performed. Wait a few minutes,
and then execute again.
C372
NNNNNYYN
A copy pair cannot be made because the specified
S-VOL is a Reserve volume.
C373
NNNNNYYN
A copy pair cannot be made because the specified
P-VOL is a Reserve volume.
C374
NNNNNYYN
The condition setting for the number of the Minim-
um Path is incorrect (multiple CU number setting
or path blocking issue).
C378
NNNNNYYN
The condition setting for the number of the Minim-
um Path is incorrect (path problem or invalid path).
C379
NNNNNYYNThe subsystem level cache of the RCU is not valid.
C37C
NNNNNYYNThe RCU is not NVS ON.
C37D
NNNNNYYNThe device level cache of the S-VOL is not valid.
C37E
Storage system sense byte information262