HP XP P9000 Smart Manager for Mainframe Messages (TB589-96003, July 2013)
Explanation and recommended actionsMessage textMessage ID
The STGADMIN.YKA.BCM.YKQUERY or
STGADMIN.YKA.BCM.COMMANDS profile is not defined in the FACILITY
class of the RACF.
Review the RACF settings and then restart the Business Continuity
Manager agent.
xxxxxxxx
Maintenance information
THE PROFILE IS NOT DEFINED IN
THE FACILITY CLASS OF RACF:
xxxxxxxx
YKY020I CON
The command cannot be executed because a NAME/TOKEN write error
occurred. The Business Continuity Manager agent will now stop.
return-code
Return code set by the NAME/TOKEN registration routine (IEANTCR)
name
Name registered in the NAME/TOKEN service
A NAME/TOKEN WRITE ERROR
OCCURRED,RC=return-
code,NAME=name
YKY021I CON
The specified prefix is being used by another program.
Check the initialization parameters.
THE SPECIFIED PREFIX IS BEING
USED BY ANOTHER PROGRAM
YKY022I CON
The Business Continuity Manager agent was terminated.AGENT ENDEDYKY051I CON
The Business Continuity Manager agent termination processing has
begun.
AGENT IN SCHEDULED SHUT-
DOWN
YKY052I CON
The Business Continuity Manager agent terminated abnormally.
If the cause is unknown, collect the ABEND dump in the SYSABEND
dump format and then contact customer support for investigation.
AGENT ABENDEDYKY053I CON
Table 32 List of messages (message ID YKY1x)
Explanation and recommended actionsMessage textMessage ID
The MODIFY command was accepted.
MODIFY COMMAND ACCEPTEDYKY100I CON
The STOP command was accepted.
STOP COMMAND ACCEPTEDYKY101I CON
After an entry of the MODIFY command, an error was detected in the
command or operand shown as text.
Check, and, if necessary, revise the command.
error-type
• COMMAND: Indicates that an error was detected in the command.
• OPERAND: Indicates that an error was detected in the operand.
INVALID error-type: text
YKY102I CON
The entered command has a syntax error.
Check, and, if necessary, revise the command.
COMMAND SYNTAX ERRORYKY103I CON
The specified operand is invalid.
Correct the error and then re-enter the operand.
OPERAND IS INCORRECTYKY104I CON
The value of the initialization parameter has been changed. The
parameter name is given in parameter-name.
parameter-name WAS
CHANGED
YKY111I CON
Messages144