HP XP P9000 Smart Manager for Mainframe Messages (TB589-96003, July 2013)

Explanation and recommended actionsMessage textMessage ID
An error occurred during execution of the YKWATCH command. The
YKCONMSG command issued within the YKWATCH command cannot be
executed correctly.
rrrr
Return code of the YKCONMSG command
For details, see the description for the YKCONMSG command in the
HP XP P9000 for Business Continuity Manager Software Reference
Guide.
Processing error encountered. Reas-
on code = rrrr
YKW010E TSO
The YKWATCH command detected an invalid startup parameter.Invalid parameter-reason-message
YKW098E TSO
This message is issued to notify the user that the copy group identified
by copy-group entered the requested status identified by state.
copy-group
Copy group ID
Group copy-group has reached
the desired state state.
YKW099I TSO
Table 28 List of messages (message ID YKX0x)
Explanation and recommended actionsMessage textMessage ID
Invalid parameters are specified.
For details, see the reason code in the YKX099I message that will
appear after this message. For reason codes, see IKJPARS in the TSO/E
Programming Services.
Supplied parameters invalidYKX000T TSO
Nothing is assigned to the MSG parameter.
No message MSG() suppliedYKX001E TSO
Nothing is assigned to the SN parameter.
No serial# SN() supplied
YKX001E MSG
SC=48
The last character of the MSG parameter is not a period.
stem
Stem name assigned to the MSG parameter
Messages MSG(stem) does not in-
clude trailing "."
YKX002E TSO
Access to the REXX variable identified by name failed.
For details about the return code, see IKJCT441 in the TSO/E
Programming Services.
nnnn
Error code returned upon REXX access
REXX failure return code=nnnn
starting with variable name
YKX010E TSO RC=40
The command device definition for the storage system identified by
serial-number failed.
If multiple command devices are defined for the storage system,
processing continues.
Operate according to the I/O error messages issued simultaneously.
serial-number
Serial number of the corresponding storage system
apid
APID of the command device that failed to be defined
Storage system serial-number
Command Device Definition Failed.
(APID=apid)
YKX065W MSG
SC=4 RC=0
Messages 139