HP XP P9000 RAID Manager Reference Guide (T1610-96061, January 2014)
Returned values
--
Error codes
--
Examples
Example 1
Example of raidvchkdsp command with -fd option:
raidvchkdsp -g vg01 -fd -v cflag
Group PairVol Device_File Seq# LDEV# BR-W-E-E MR-W-B BR-W-B
SR-W-B-S
vg01 oradb1 Unknown 2332 - - - - - - - - - - -
- - - -
vg01 oradb2 c4t0d3 2332 3 D E B R D D D D E E
D E D D
Example 2
Example of raidvchkdsp command with -fe option and its output:
# raidvchkdsp -g horc0 -v gflag -fe
Group... TID LU Seq# LDEV# GI-C-R-W-S PI-C-R-W-S R-Time EM E-Seq# E-LDEV#
horc0... 0 20 63528 65 E E E E E E E E E E 0 - -
-
horc0... 0 20 63528 66 E E E E E E E E E E 0 - -
-
Output of the raidvchkdsp command with -fe option:
EM: external connection mode.
• H = Mapped E-lun is hidden from the host.
• V = Mapped E-lun is visible to the host.
• — = Unmapped to the E-lun.
• BH = Mapped E-lun as hidden from the host, but LDEV blockading.
• BV = Mapped E-lun as visible to the host, but LDEV blockading.
• B = Unmapped to the E-lun, but LDEV blockading.
E-Seq#: production (serial) number of the external LUN ('Unknown' shown as '-').
E-LDEV#: LDEV# of the external LUN ('Unknown' shown as '-').
Example 3
Example of raidvchkdsp command with -v cflag option and its output:
raidvchkdsp -g vg01 -fd -v cflag
Group PairVol Device_File Seq# LDEV# BR-W-E-E MR-W-B
BR-W-B-Z SR-W-B-S
vg01 oradb1 c4t0d2 2332 2 D E B R D D D
D E E E D E D D
vg01 oradb2 c4t0d3 2332 3 D E B R D D D
D E E E D E D D
Output of the raidvchkdsp command with -v cflag option:
BR-W-E-E: Displays the flags for checking data block size.
R=E: Checking for data block size on Read is enabled.
R=D: Checking for data block size on Read is disabled.
82 Data management commands