HP XP P9000 RAID Manager Reference Guide (T1610-96061, January 2014)

Returned values
--
Error codes
--
Examples
raidscan command examples for fibre-channel ports
# raidscan -p cl1-r
PORT#/ALPA/C,TID#,LU#Num(LDEV#...)P/S,Status,Fence,LDEV#,P-Seq#P-LDEV#
CL1-R/ ce/15,15, 7 5(100,101..)P-VOL PAIR NEVER 100,5678 200
CL1-R/ ce/15,15, 6 5(200,201..)SMPL ---- ---- ---- ---- -----
# raidscan -p cl1-r -f
PORT#/ALPA/C,TID#,LU#Num(LDEV#...)P/S,Status,Fence,LDEV#,Vol.Type
CL1-R/ ce/15,15, 7 5(100,101..)P-VOLPAIRNEVER100,OPEN-3
CL1-R/ ce/15,15, 6 5(200,201..)SMPL------------OPEN-3
Example of -find option for raidscan
# ls /dev/rdsk/* | raidscan -findDEVICE_FILE UID S/F PORT TARG LUN SERIAL LDEV PRODUCT_ID
/dev/rdsk/c0t0d4 0 S CL1-M 0 4 31168 216 OPEN-3-CVS-CM
/dev/rdsk/c0t0d1 0 S CL1-M 0 1 31168 117 OPEN-3-CVS
/dev/rdsk/c1t0d1 - - CL1-M - - 31170 121 OPEN-3-CVS
Output of the raidscan command:
Port#, ALPA/C, TID#, LU#: port ID, arbitrated loop physical address, target ID, LUN.
For Business Copy, raidscan displays the MU# for each LUN (for example, LUN 7-0, 7-1, 7-2).
Num(LDEV#…): number of LDEVs and LDEV ID for a LUSE volume
P/S: volume attribute
Status: status of the paired volume
Fence: fence level (Continuous Access Synchronous only)
P-Seq#: serial # of the storage system which contains the partner volume of the pair
P-LDEV#: LDEV number of the partner volume of the pair
Vol.Type: logical unit (LU) type (for example, OPEN-V, OPEN-9)
Group: group name (dev_group) as described in the configuration definition file
UID: Displays the unit ID for multiple storage system configuration. If UID appears as '-', the
command device for HORCM_CMD is not found.
S/F: Displays whether the port is SCSI or fibre
PORT: Displays the RAID storage system port number
TARG: Displays the target ID (that was converted by the fibre conversion table)
LUN: Displays the LUN (that was converted by the fibre conversion table)
SERIAL: Displays the production (serial#) number of the RAID storage system
LDEV: Displays the LDEV# within the RAID storage system
PRODUCT_ID: Displays product-id field in the STD inquiry page
raidar
The raidar command displays configuration, status, and I/O activity information for the specified
port/TID(s)/LUN at the specified time interval. The configuration information is acquired directly
from the storage system (not from the configuration definition file).
raidar 73