HP XP P9000 RAID Manager Reference Guide (T1610-96061, January 2014)

Table 17 Specific error codes for horctakeover (continued)
ValueRecommended ActionError MessageError CodeCategory
235Confirm pair status using pairdisplay,
and change combination of volumes.
Pair Volume
combination error
EX_EVOLCE
225Check volume list to see if an operation
was directed to the wrong S-VOL.
S-VOL currency errorEX_VOLCUR
224Confirm pair status of the local volume.Local Volume currency
error
EX_VOLCUE
223Confirm pair status of remote and local
volumes using pairdisplay command.
Local and Remote
Volume currency error
EX_VOLCRE
233Increase timeout value using -t option.Timeout waiting for
specified status
EX_EWSTOTTimer
(Recoverable)
raidscan
The raidscan command displays configuration and status information for the specified
port/TID(s)/LUN/MU#. The information is acquired directly from the storage system (not the
configuration definition file).
Syntax
raidscan { -h | -q | -z | -I[H][M][instance#] or
-I[TC][SI][instance#] | -p <port> [hgrp]|-pd[g] <raw_device>
| -s <Seq#> | -t <targ> | -l <lun> | [ -f[xfgde] ] | -CLI
| -find[g] [op] [MU#] | [-g <group>] | -pi <strings>
| -m <MU#>}
Options and parameters
DescriptionOption
Displays Help/Usage and version information.-h
Terminates the interactive mode and exits the command.-q
Makes the raidscan command enter the interactive mode. The -zx option guards performing of
the HORCM in the interactive mode. When this option detects a HORCM shut down, interactive
mode terminates.
-z or -zx
OpenVMS cannot use the -zx option.
Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business
Copy], and used when specifying the RAID Manager instance number.
-I[H][M] [instance#]
or
-I[TC][SI] [instance#]
Specifies the port ID of the port to be scanned. Valid ports are CL1-A to CL1-R and CL2-A to
CL2-R (excluding CL1-I, CL1-O, CL2-I, CL2-O). In case of the expanded port, specify from
-p <port> [hgrp]
following: CL3-a to CL3-r (excluding CL3-i and CL3-o), or CLG-a to CLG-r (excluding CLG-i and
CLG-o).
The port is not case sensitive (for example, CL1-A= cl1-a= CL1-a= cl1-A, CL3-a= CL3-A= cl3-a=
cl3-A).
This option must be specified if '-find' or '-pd <raw_device>'option is not specified.
[hgrp] is specified to display only the LDEVs mapped to a host group on a port (XP1024/XP128
Disk Array and later).
Specifies the raw device name. This option finds Seq# and port_name of the storage system to
which the specified device can be connected, and scans the port of the storage system which
-pd[g] <raw_device>
corresponds with the unit ID that searches the unit ID from Seq#. This option must be specified
68 Data management commands