HP XP P9000 RAID Manager Reference Guide (T1610-96061, January 2014)

DescriptionOption
- -
homrcf1 deva2 L CL1-D 3 5 2 30053 271 SMPL - -
- -
Used when displaying a paired status of each mirror descriptors for the specified pair logical
volume, and used for paired status indication of the cascading volume. The <mode> option can
be designated 'cas' or 'all' :
-m <mode>
The 'cas' option is used when displaying a paired status of specified group that is registered
to the mirror descriptor (MU#) on the cascading configuration file.
The 'all' option is used when displaying a paired status of all mirror descriptors (MU#).
This option (-m <mode>) is not affected with command execution environment (Continuous
Access Synchronous/Continuous Access Synchronous Async/Continuous Access Journal and
Business Copy/Snapshot /Auto LUN), and displays the paired status. This option cannot be
specified with the -FHORC/-FMRCF option on the same command line.
Displays the JNL status for the local and remote interconnected to the group. Also finds the
journal ID for each local and remote interconnected to the group via the specified group or
-v jnl[t]
<raw_device>, and displays information of each journal ID corresponding the local and remote.
The first line shows the journal information for the local host, second line shows the journal
information for the remote host. The item for displaying is the same as raidvchkscan -v jnl[t].
Example:
# pairdisplay -g VG01 -v jnl
JID MU CTG JNLS AP U(%) Q-Marker Q-CNT D-SZ(BLK) Seq# Nnm LDEV#
001 0 2 PJNN 4 21 43216fde 30 512345 62500 2
265
002 0 2 SJNN 4 95 3459fd43 52000 512345 62538 3
270
Example:
# pairdisplay -g VG01 -v jnlt
JID MU CTG JNLS AP U(%) Q-Marker Q-CNT D-SZ(BLK) Seq# DOW
PBW APW
001 1 2 PJNN 4 21 43216fde 30 512345 62500 20
300 40
002 1 2 SJNN 4 95 3459fd43 52000 512345 62538 20
300 40
Example:
# pairdisplay -g VG01 -v jnl -FCA 1
JID MU CTG JNLS AP U(%) Q-Marker Q-CNT D-SZ(BLK) Seq# Nnm
LDEV#
003 1 2 PJNN 4 21 43216fde 30 512345 62500 2
265
Notes:
This option can be specified with following options on the same command line:
{-g<group> | -d <pair Vol> | -d[g] <raw_device> [MU#] | -FCA [MU#] | -d[g] <seq#> <LDEV#> [MU#] |
-l | -f[x] }
The '-FHORC [MU#]' or '-FCA [MU#]' option is used when displaying the journal information
of cascading Continuous Access Journal volume, and then it shows the journal information
for the remote host only.
This option displays nothing if the target volume is NOT a Continuous Access Journal volume.
This option finds the CT group for each local and remote interconnected to the group via the
specified group or <raw_device>, and displays any information of each CT group corresponding
-v ctg
the local and remote. The first line shows the CT group information for the local host, second
line shows the CT group information for the remote host.
Example:
# pairdisplay -g VG01-v ctg
pairdisplay 59