HP XP P9000 RAID Manager Reference Guide (T1610-96061, January 2014)
DescriptionOption
Specifies the port number on the MCU.-mcu_port <port#>
Specifies the port number on the RCU (storage system port on the remote side).-rcu_port <port#>
Specify the port that the attribute is MCU initiator port (MCU) or RCU target port (RCU).
Examples
To the RCU for which the product number: 64034, the RAID type: R700 and the path ID: 1 are
set, adding RCU path: mcu port: CL1-A, rcu port CL1-B.
# raidcom add rcu_path -cu_free 64034 R700 1 -mcu_port CL1-A
-rcu_port CL1-B
raidcom delete rcu_path
Deletes logical paths from a specified RCU.
This command is executed asynchronously with the command input. Check the completion of this
process on the raidcom get command_status command.
Syntax
raidcom delete rcu_path {-rcu <serial#> <mcu#> <rcu#>
-ssid <ssid> | -cu_free <serial#> <id> <pid>} -mcu_port
<port#> -rcu_port <port#>
Options and parameters
DescriptionOption
Specifies the CU by serial number, <mcu#>, and <rcu#>. You can use hexadecimal
numbers (add 0x prefix ) or decimal numbers for the <mcu#> and <rcu#>.
-rcu <serial#> <mcu#> <rcu#>
Specifies the subsystem ID.-ssid <ssid>
You can use hexadecimal numbers (add 0x prefix) or decimal numbers for the <ssid>.
This parameter is used to specify CU free specified by Serial#, id#, pid#.-cu_free <serial#><id><pid>
< id > specifies the storage system type as follows:
• For P9500 use R700.
• For XP24000/XP20000 Disk Array use R600.
• For XP12000 Disk Array/XP10000 Disk Array use R500.
< pid> specifies the path group ID (1-255).
Note:
The RCU is displayed by default on the GUI of Continuous Access Synchronous,
Continuous Access Journal, or Continuous Access Journal Z when "0" is specified for
<pid>.
Specifies the port number on the MCU.-mcu_port <port#>
Specifies the port number on the RCU (storage system port on the remote side).-rcu_port <port#>
Specifies the port that the attribute is MCU initiator port (MCU) or RCU target port
(RCU).
Examples
From the RCU for which the product number: 64034, the RAID type: R700 and the path ID: 1 are
set, deleting RCU path: mcu port: CL1-A and rcu port CL1-B.
# raidcom delete rcu_path -cu_free 64034 R700 1 -mcu_port CL1-A
-rcu_port CL1-B
196 Configuration setting commands