HP XP P9000 RAID Manager Reference Guide (T1610-96061, January 2014)
-MCU: Displays the CU number (hexadecimal) as MCU. If CU free is specified for RCU, "-" is
displayed.
-RCU: Displays the CU number (hexadecimal) as RCU. If CU free is specified for RCU, "-" is
displayed.
-M/R: Displays the CU type as MCU/RCU.
-T: Displays the type of physical path: F: FIBRE, E:ESCON.
-PNO: Displays the path number.
-MPORT: Displays the MCU port number.
-RPORT: Displays the RCU port number.
-STS_CD: Displays the following path status:
• - NML_01: Normal
• - ERR_02: Initialization failed
• - ERR_03: Communication timeout
• - ERR_04: Logical blockade
• - ERR_05: Resource Shortage
• - ERR_06: Serial Number Mismatch
• - ERR_10: Invalid Port
• - ERR_80: RCU Port Number Mismatch
• - ERR_81: RCU Port Type Mismatch
• - ERR_82: Communication Failed.
If the path creation or the path deletion is in progress, "-" is displayed.
-SSIDs: Displays the SSIDs (hexadecimal) setting to RCU. If CU free is specified for RCU, "-" is
displayed.
raidcom modify rcu
This sets the control parameters to specified CU that is specified using two way.
Syntax
raidcom modify rcu {-rcu <serial#> <mcu#> <rcu#> -ssid <ssid>
| -cu_free <serial#> <id> <pid>} -rcu_option <mpth> <rto>
<rtt> [fzd | fze]
Options and parameters
DescriptionOption
Specifies the CU specified by serial number, <mcu#>, <rcu#>. You can use hexadecimal
numbers (add "0x" prefix) or decimal numbers for <mcu#> and <rcu#>.
-rcu <serial#> <mcu#>
<rcu#>
Specifies the subsystem ID.-ssid <ssid>
You can use hexadecimal numbers (add 0x prefix) or decimal numbers for the <ssid>.
Specifies CU free specified by serial#, id#, pid# for setting CU for the operational
object.
-cu_free <serial#><id><pid>
< id > specifies the storage system type as follows:
• For P9500 use R700.
• For XP24000/XP20000 Disk Array use R600.
• For XP12000 Disk Array/XP10000 Disk Array use R500.
194 Configuration setting commands