HP XP P9000 RAID Manager Reference Guide (T1610-96061, January 2014)
# raidcom get rcu
Serial# ID PID MCU RCU M/R T STS MP NP IM FZ RTO(s) RTT(ms)
64034 R7 - 1C 23 RCU F NML 4 8 MR D 15 20
64034 R7 - 1C 23 RCU F NML 4 8 RO E 15 20
64034 R7 1 - - MCU E NML 4 8 - - 15 20
Description of each column in output example
Serial#: Product serial number.
ID: Displays the ID for identifying RAID type: R7 = P9500, R6 = XP24000/XP20000 Disk Array,
R5 = XP12000 Disk Array/XP10000 Disk Array
PID: Displays a path group ID. If CU is specified for RCU, "-" is displayed.
MCU: Displays the CU number (hexadecimal) as MCU. If CU free is specified for RCU, "-" is
displayed.
RCU: Displays the CU number (hexadecimal) as RCU. If CU free is specified for RCU, "-" is
displayed.
M/R: Displays the CU type as MCU/RCU.
T: Displays the type of physical path, F:FIBRE, E:ESCON
STS: Displays the following status of the CU.
• NML: Normal
• WAR: Warning
• ERR: Failing
• UNK: Unknown, displayed when the target of the pair is MCU.
MP: Displays the number of path as minimum.
NP: Displays the number of path setting between MCU and RCU.
IM: Displays the incident mode setting to RCU.
• MR: it sends incident to MCU host and RCU host
• RO: it sends incident only to RCU host
• If CU free is specified for RCU, "-" is displayed.
FZ: Displays the freeze option.
• D: the freeze option is disabled.
• E: the freeze option is enabled.
• -: "-" is displayed when CU free is specified for RCU.
RTO (s): Displays the timeout value for RIO (Remote IO) setting between MCU and RCU.
RTT (ms): Displays the round trip time value between MCU and RCU.
# raidcom get rcu -cu_free 64034 R700 1
Serial# ID PID MCU RCU M/R T PNO MPORT RPORT STS_CD SSIDs …
64034
R7 1 - - RCU F 1 CL1-A CL1-B NML_01 -
64034 R7 1 - - RCU F 2 CL1-A CL1-B NML_01 -
64034 R7 1 - - RCU F 3 CL1-A CL1-B NML_01 -
Description of each column in output example
-Serial#: Product serial number.
-ID: Displays the ID for identifying RAID type: XP12000 Disk Array/XP10000 Disk Array :R5,
XP24000/XP20000 Disk Array : R6, P9500 : R7
PID: Displays the path group ID. If CU is specified for RCU, "-" is displayed.
raidcom get rcu 193