HP XP P9000 RAID Manager Reference Guide (T1610-96061, January 2014)

Subcommands
RAID Manager provides subcommands that are executed as options of RAID Manager commands.
The RAID Manager subcommands include the Windows subcommands and the environment
variable subcommands. Table 3 (page 18) lists the Windows subcommands in alphabetical order
and provides a brief description of each subcommand. Table 4 (page 18) lists the environment
variable subcommands in alphabetical order and provides a brief description of each subcommand.
Table 3 Windows subcommands
DescriptionSubcommand
Displays the relationship between the disk numbers assigned by the Windows system and
the LDEVs on the RAID storage system, and also displays attribute and status information
for each LDEV.
drivescan
Searches for command devices within the specified range of disk drive numbers. If it is
found, the command device appears in the same format as in the configuration definition
findcmddev
file. This subcommand is used when the command device name is not known and when
the HORCM is not started.
Mounts the specified drive to the specified partition on the specified data drive using the
drive letter. When the mount subcommand is executed without an argument, all currently
mount
mounted drives (including directory mounted volumes) are displayed, and logical drive has
been mounting an LDM volume then displays Harddisk#[n] configured an LDM volume.
Displays the devices on the specified port(s).portscan
The sync (synchronization) Windows subcommand sends unwritten data remaining on the
Windows server to the specified device(s) to synchronize the pair(s) before the RAID
Manager command is executed.
sync and syncd
The syncd (sync delay) Windows subcommand waits the delayed IO for dismount after
issued 'sync'.
Table 4 Environment variable subcommands
DescriptionSubcommand
Displays the environment variables.env
Sets the specified environment variables.setenv
Causes RAID Manager to wait for the specified time.sleep
Deletes the specified environment variables.usetenv
Command tools
Table 5 (page 18) lists and describes the RAID Manager command tools.
Table 5 Command tools
DescriptionSubcommand
Used to confirm the drive connection between the storage system and host system. The
inqraid command displays the relation between special file(s) on the host system and actual
physical drive of the RAID storage system.
inqraid
Used to make a configuration file from a special file (raw device file) provided via STDIN.mkconf
Scriptable command used to associate pair operation commands and raidcom commands.rmawk
18 Overview of commands