HP XP P9000 RAID Manager Reference Guide (T1610-96061, January 2014)

Table 1 Data management commands (continued)
DescriptionCommand
Obtains the pair status transition of each volume pair and reports it. If the pair status changes
(due to an error or a user-specified command), the pairmon command issues a message.
pairmon
Re-establishes a split pair volume and then restarts the update copy operations to the
secondary volume. The pairresync command can resynchronize either a paired logical
volume or a group of paired volumes.
pairresync
Splits and deletes volume pairs.pairsplit
Used to confirm data consistency between the Continuous Access Synchronous
Async/Continuous Access Journal P-VOL and S-VOL by confirming that required writing
pairsyncwait
was stored in the DFW area of RCU, and confirming whether the last writing just before
this command reached the RCU DFW area.
Checks the attributes and status of a pair volume. It acquires and reports the attribute of a
volume or group connected to the local host (issuing the command) or remote host. The
volume attribute is SMPL (simplex), P VOL (primary volume), or S VOL (secondary volume).
pairvolchk
Displays the status and I/O activity information for the specified port/TID(s)/LUN(s) at the
specified time interval. The configuration information is acquired directly from the storage
system (not from the configuration definition file).
raidar
Displays the configuration of the connected host and RAID storage system.raidqry
Displays the status information for the specified port/TID(s)/LUN(s)/MU#(s). The information
is acquired directly from the storage system (not the configuration definition file).
raidscan
Displays the parameters for data validation of the specified volumes. Unit of checking for
the validation is based on the group of RAID Manager configuration definition file.
raidvchkdsp
Displays the fibre port of the storage system (XP1024/XP128 Disk Array and later), target
ID, LDEV mapped for LUN#, and LDEV status, regardless of the configuration definition
file.
raidvchkscan
Supports the (-v jnl [t] [unit#]) option to find the journal volume list setting. It also displays
any information for the journal volume. The Continuous Access Journal function is available
raidvchkscan (for Cnt
Ac-J/Cnt Ac-J Z)
on the XP24000/XP20000 Disk Array and XP12000 Disk Array/XP10000 Disk Array
storage systems.
Supports the option (-v pid[a] [unit#]) to find the Fast Snap, Snapshot, or Thin Provisioning
pool settings, and displays information for the Fast Snap, Snapshot, or Thin Provisioning
pool.
raidvchkscan (for Fast
Snap, Snapshot, or Thin
Provisioning pool)
You can set the parameters for data validation of the specified volumes. You also can set
to off all of the validation checking without specifying [type]. Unit of checking for the
validation is based on the group of RAID Manager configuration definition file.
raidvchkset
Configuration setting commands
Table 2 (page 15) lists and describes the RAID Manager configuration setting commands. The
configuration setting commands include all commands that begin with "raidcom".
Table 2 Configuration setting commands
DescriptionCommand
Creates a host group.raidcom add host_grp
Deletes a host group.raidcom delete host_grp
Sets the host mode.raidcom modify host_grp
Displays the host group information.raidcom get host_grp
Registers a host to a host group.raidcom add hba_wwn
Deletes a host (WWN) from a host group.raidcom delete hba_wwn
Summary of commands 15