HP XP P9000 RAID Manager Reference Guide (T1610-96061, January 2014)

Options and parameters
DescriptionOption
Specifies the external VOL path group number (0-63231).-path_grp <path group#>
Specifies the external volume group number (gno:1-16384, sgno:1-4096). For example:
52-11
-external_grp_id
<gno-sgno>
Specifies the port number. Specifies the port number whose attribute is External. For
example:
CL1-A
Displays an external port.
-port <port#>
Specifies the WWN value (hexadecimal value) of the external storage system in 8 bytes.
The value can be split in units of 4 bytes by "," (commas). For example:
-external_wwn <wwn
strings>
21000e08b0256f8
21000e0,8b0256f8
Displays LUN (0-2047) of the external storage system port.-lun_id <lun#>
Specifies the emulation type. If this option is omitted, OPEN-V is used.[-emulation <emulation
type> ]
The valid values for <emulation type> are:
OPEN-3, OPEN-8, OPEN-9, OPEN-E, OPEN-K, OPEN-L, OPEN-V
3390-1, 3390-2, 3390-3, 3390-A, 3390-3A, 3390-3B, 3390-3C, 3390-3R, 3390-9,
3390-9A, 3390-9B, 3390-9C, 3390-L, 3390-LA, 3390-LB, 3390-LC, 3390-M,
3390-MA, 3390-MB, 3390-MC, 3390-V
3380-3, 3380-3A, 3380-3B, 3380-3C
6586-G, 6586-J, 6586-K, 6586-KA, 6586-KB, 6586-KC6588-1, 6588-3, 6588-9,
6588-3A, 6588-3B, 6588-3C, 6588-9A, 6588-9B, 6588-9C, 6588-L, 6588-LA,
6588-LB, 6588-LC
Some emulation types cannot be specified according to the type of device.
CAUTION: You can specify 3390-3 or 3390-3R as the emulation type, but these are
unable to be mixed. You can specify the 3380 series or the 3390 series as the emulation
type for each parity group, but they are unable to be mixed for each 32 address boundary
because of the OS restriction. You can specify the 6588 series or the 6586 series as the
emulation type for each parity group, but they are unable to be mixed for each 32 address
boundary because of the OS restriction.
Specifies the CLPR number.[-clpr <clpr#>]
Example
Mapping an LU: 0 defined to the external storage system port: 50060e80,05fa0f36 connected
to the port: CL1-A (External port) by the External Volume Group#1-1 and the path group#1.
# raidcom add external_grp -path_grp 1 -external_grp_id 1-1
-port CL1-A -external_wwn 50060e80,05fa0f36 -lun_id 0
raidcom check_ext_storage external_grp
Specifies the external volume group, check the connection for the external VOL, and then restart
using. Only one external VOL is operated in each operation.
An LDEV or device group can be specified instead of an external volume group.
If an LDEV is specified, RAID Manager finds the external volume groups to which the specified
LDEV belongs and displays the result.
If a device group is specified, RAID Manager finds the external volume groups to which the
specified device group belongs and displays the result.
142 Configuration setting commands