HP XP P9000 Provisioning for Mainframe Systems User Guide

Table Of Contents
Mainframe systemParameter
65,280Maximum number of volumes (normal and
Virtual LVI per storage system
1 user cylinder (+ control cylinders)Minimum size for one Virtual LVI volume
See “CV capacity by emulation type for mainframe systems” (page 35)Maximum size for one Virtual LVI volume
1 user cylinderSize increment
CV capacity by emulation type for mainframe systems
Number of control cylinders
(cyl)
Maximum CV capacity (cyl)Minimum CV capacity
(cyl)
Emulation type
73,33913380-3
73,33913380-3A
73,33913380-3B
73,33913380-3C
63,33913390-3
63,33913390-3A
63,33913390-3B
63,33913390-3C
63,33913390-3R
2510,01713390-9
2510,01713390-9A
2510,01713390-9B
2510,01713390-9C
2332,76013390-L
2332,76013390-LA
2332,76013390-LB
2332,76013390-LC
5365,52013390-M
5365,52013390-MA
5365,52013390-MB
5365,52013390-MC
7 cyl per 1,113 cyl
2
262,66813390-A
1
0For an internal volume:
837,760
443390-V
2,3,4
For an external volume:
1,117,760
Notes:
1. For 3390-A, the incremental unit of the CV capacity within the first 65,520 cylinders is 1 user-cylinder, and the
incremented capacity between 65,521 and 262,668 cylinders is the 1,113 user-cylinder. Therefore, if you specify
a value in Remote Web Console in the Create LDEVs window that exceeds 65,520 cylinders, the value is changed
VLL specifications 35