HP XP P9000 for Business Continuity Manager Software User Guide (T5253-96081, July 2013)

Operating procedure during a primary site storage system failure (volatile)
The following are the procedures that must be performed when a volatile failure occurs in the
primary site storage system.
The procedure below applies when you perform a failover to remote site 1. To perform a failover
to remote site 2, you need to delete the Continuous Access Journal Z copy pair between the primary
site and remote site 1, and perform a Reverse Resync for the Continuous Access Journal Z copy
pair between the primary site and remote site 2.
Failover
1. From remote site 1, execute the YKRECVER command for the Continuous Access Journal Z
copy pair between the primary site and remote site 2.
YKQUERY
YKRECVER
YKEWAIT GOTO(SIMPLEX) NOINVALIDCHECK
2. From remote site 1, execute the YKSUSPND REVERSE command for the Continuous Access
Journal Z copy pair between the primary site and remote site 1.
YKQUERY
YKSUSPND REVERSE
YKEWAIT GOTO(SUSPEND) NOINVALIDCHECK
3. From remote site 1, execute the YKRESYNC REVERSE command for the Continuous Access
Journal Z copy pair between the primary site and remote site 1.
Because a failure has occurred in the primary site storage system, an attempt to perform a
Reverse Resync fails, and the copy direction is not reversed.
368 Maintenance and troubleshooting operations