HP XP P9000 for Business Continuity Manager Software User Guide (T5253-96081, July 2013)
Table 50 Required Configuration Files (3DC Multi-Target (Cnt Ac-S Z x Cnt Ac-J Z)
Configuration) (continued)
RemarksDescriptionItem
—The route list defined for a 3DC
Multi-Target (Cnt Ac-S Z x Cnt Ac-J Z)
Route list definition file
and command device
definition file configuration must differ from that for a
3DC Cascade (Cnt Ac-S Z x Cnt Ac-J Z)
configuration for failover and failback.
Prepare the following route lists by
referring to Table 51 (page 173):
• Route list that is required when all
sites are available
• Route list used when a failure occurs
at a site (recommended)
This item is not necessary if you use
Remote Web Console to set up logical
paths.
The following path sets are required for
logical paths.
Path set definition file
• An inter-control unit logical path is
required between the primary site and
the local site (for both directions).
• An inter-disk controller logical path is
required between the primary site and
the remote site (for both directions).
The following table describes the route list necessary for operation in a 3DC Multi-Target (Cnt Ac-S
Z x Cnt Ac-J Z) configuration.
Table 51 Required route list (3DC Multi-Target (Cnt Ac-S Z x Cnt Ac-J Z) configuration)
Route list needed in Business Continuity ManagerRemote site
condition
Local site
condition
Primary site
condition
Host on which Business
Continuity Manager is
started
Primary → LocalUsableUsableUsablePrimary host
Primary → Remote
Primary → LocalUnusableUsableUsable
Primary → RemoteUsableUnusableUsable
Primary
#
UnusableUnusableUsable
Local → Primary → RemoteUsableUsableUsableLocal host
Local → PrimaryUnusableUsableUsable
Local → RemoteUsableUsableUnusable
Local
#
Local
#
UnusableUsableUnusable
Remote → Primary → LocalUsableUsableUsableRemote host
Remote → PrimaryUsableUnusableUsable
NoneUsableUsableUnusable
UsableUnusableUnusable
Legend:
Usable: The target site can be used.
Unusable: The target site cannot be used because of an error.
Defining a 3DC Multi-Target (Cnt Ac-S Z x Cnt Ac-J Z) configuration 173