HP XP P9000 for Business Continuity Manager Software Release Notes
Table Of Contents
- HP XP P9000 for Business Continuity Manager Software 7.6.0-00
- Description
- Operating systems
- License keys
- Product models
- Devices supported
- Languages
- New features and important enhancements
- Prerequisites
- Prerequisite programs
- Related programs
- Memory and disk space requirements
- Virtual memory space requirements
- Fixes
- Resolved issues
- Installation instructions
- Installation precautions
- Determining current version
- Version description
- User SVC version that corresponds to this product version
- Compatibility/interoperability
- System configuration
- Remote DKC control function
- Copy types
- Other
- Temporary restrictions
- Specification differences from previous versions
- 4x4x4 Multi-Target configuration with Delta Resync
- Overview of CLI commands for 4x4x4 Multi-Target configuration with Delta Resync
- Documentation feedback

Table 20 Operation procedure of 4x4x4 Multi-Target configuration with Delta Resync
Difference from 3DC
Multi-Target configuration
ConfigurationDescriptionOperation procedure#
Preparation
Arbitration paths and
command devices for 4x4
configuration are necessary.
1DCHardware setup1
• Bi-directional paths must be set
between P-L, P-R and L-R sites.
• One or more Journal groups in
each site.
• Arbitration paths and arbitration
command devices.
A command device is
necessary for each DKC.
1DCCreate a route list of 3DC
Multi-Target configuration that
Route list2
contains definition or routes that start
from each site. This route list is
equivalent to that of 3DC Multi-Target
configuration with Delta Resync.
Once a route list is defined, establish
routes according to the route list.
Cnt Ac-S must be with C/T ID,
and Cnt Ac-J must be of 4x4
1DCCreate a copy group definition file
for TC between P-site and L-site
Definition of copy pairs3
Cnt Ac-J. See Table 18 (page
15) for more details.
(G1/G4), 4x4 Cnt Ac-J between
P-site and R-site (G2/G5), and 4x4
Cnt Ac-J between L-site and R-site
(G3/G6).
None2DCEstablish Cnt Ac-S copy group
(G1/G4).
Establish Cnt Ac-S copy
pairs (G1/G4)
4
None3DCEstablish Cnt Ac-J copy group
(G2/G5).
Establish Cnt Ac-J copy
pairs (G2/G5)
5
None3DCEstablish Delta Resync Cnt Ac-J copy
group (G3/G6) into HOLD status.
Establish Delta Resync Cnt
Ac-J copy pairs (G3/G6)
6
Normal operation
None3DCKeep DUPLEX status on both Cnt Ac-S
(G1/G4) and Cnt Ac-J (G2/G5)
copy groups.
....7
Documentation feedback
HP is committed to providing documentation that meets your needs. To help us improve the
documentation, send any errors, suggestions, or comments to Documentation Feedback
(docsfeedback@hp.com). Include the document title and part number, version number, or the URL when
submitting your feedback.
Documentation feedback 17