HP XP P9000 for Business Continuity Manager Software Release Notes

Table 16 Prerequisite software
DescriptionItem
Versions supported by BCM V7.6.0z/OS or OS/390 V2R10
V7.6.0BCM
Basic License
Cnt Ac-J 4x4 Extended CTG License
Table 17 Storage system settings
RemarksDescriptionItem
Arbitration command devices must be set
up with Remote Web Console.
Storage systems at the remote site: One
or more arbitration command devices
for each subordinate DKC.
Arbitration command devices
Journal groups for Cnt Ac-J. Timer type
must be “System.
Journal groups
Required at the Primary, Remote, and
Local sites.
Journal groups must be set up with the
Remote Web Console before running
a script.
One or more of journal volumes are
required at each of the Primary,
Remote, and Local sites.
Journal volumes for Cnt Ac-J.Journal volumes
NoneIn 2x2x2 configuration: 3 devices for
each DKC, 18 devices in total.
Command devices
In 4x4x4 configuration: 3 devices for
each DKC, 36 devices in total.
NoneBetween the Primary and Local sites:
Inter-CU logical paths (bi-directional).
Logical paths
Between the Primary and Remote sites:
Inter-DKC logical paths (bi-directional).
Between the Local and Remote sites:
Inter-DKC logical paths (bi-directional).
14 4x4x4 Multi-Target configuration with Delta Resync