HP XP P9000 for Business Continuity Manager Software Release Notes
Table Of Contents
- HP XP P9000 for Business Continuity Manager Software 7.6.0-00
- Description
- Operating systems
- License keys
- Product models
- Devices supported
- Languages
- New features and important enhancements
- Prerequisites
- Prerequisite programs
- Related programs
- Memory and disk space requirements
- Virtual memory space requirements
- Fixes
- Resolved issues
- Installation instructions
- Installation precautions
- Determining current version
- Version description
- User SVC version that corresponds to this product version
- Compatibility/interoperability
- System configuration
- Remote DKC control function
- Copy types
- Other
- Temporary restrictions
- Specification differences from previous versions
- 4x4x4 Multi-Target configuration with Delta Resync
- Overview of CLI commands for 4x4x4 Multi-Target configuration with Delta Resync
- Documentation feedback

Table 13 Messages
Column HeadColumn HeadColumn HeadColumn Head
7.6.0-00HP storage systems Devices
Found
HP storage systems FoundYKC032I
7.6.0-00<command> detected the
<service> service error.
<command> detected the
<rexx-service> service error.
YKZ330E
(return code=<r>[, reason(return code=<r>[, reason
code=<n>]) code=<n>][, abend
code=<a>])
7.6.0-00Added.-YK7000T
YK7001E
YK7003E
YK7004E
YK7014I
YK7015I
YK7031I
YK7032I
YK7033I
YK7099I
YKZ910I
YKZ911I
4x4x4 Multi-Target configuration with Delta Resync
Additional information and updates to the 4x4x4 Mutli-Target configuration with Delta Resync
documentation.
Table 14 Additional information and documentation updates
UpdatesLocation to be updatedGuide name
In 4x4x4 Multi-Target configurations with Delta Resync,
information about an EXCTG is deleted when all copy
Add2. CLI commands
YKDELETE command
Reference Guide
pairs of either the Cnt Ac-J Z or the Delta Resync copy
Notes
group that was first registered to the EXCTG are dissolved.
For example, if the YKDELETE command is issued to Cnt
Ac-J Z copy pairs or Delta Resync pairs in HOLD status
after Delta Resync is performed, a Journal Group of Cnt
Ac-J Z copy pairs in DUPLEX is also unregistered from
the EXCTG. Therefore, if YKQUERY is issued to retrieve
copy pair information from the Cnt Ac-J Z copy pairs, the
YKZ296E message occurs. If this occurs, either issue the
YKMAKE command with the HOLD parameter to the
dissolved Cnt Ac-J Z copy pairs or Delta Resync pairs, or
issue the YKMAKE command with the SELECT(COND)
parameter to (undissolved) Cnt Ac-J Z copy pairs to
re-register them to the EXCTG.
In 4x4x4 Multi-Target configurations with Delta Resync,
information about an EXCTG is deleted when all copy
Add2. CLI commands
YKRECVER command
Reference Guide
pairs of either the Cnt Ac-J Z or the Delta Resync copy
Notes
group that was first registered to the EXCTG are dissolved.
For example, if the YKRECVER command is issued to Cnt
Ac-J Z copy pairs or Delta Resync pairs in HOLD status
after Delta Resync is performed, a Journal Group of Cnt
Ac-J Z copy pairs in DUPLEX is also unregistered from
the EXCTG. Therefore, if YKQUERY is issued to retrieve
copy pair information from the Cnt Ac-J Z copy pairs, the
YKZ296E message occurs. If this occurs, either issue the
12 4x4x4 Multi-Target configuration with Delta Resync